Use this guide to verify that the card dispenser is getting the correct voltage from the power source (control head / distribution board).

Step-by-step guide

Verify Source Voltage

  1. Set multi-meter to DC mode
  2. Connect black probe to orange pin
  3. Connect red probe to green pin
  4. Verify that multi-meter displays 12V

Wiring Reference

Pin LocationCCI Wire Color12VDC ConnectionsOperations Guide
1Orange0VSource Voltage
2Green12VDC
3
COMMON

Vend Switch

30ms or longer switch closure to vend card

4
NORMALLY OPEN
5
LIT BUTTON / LAMP

READY-TO-VEND SIGNAL

Enables a lamp to be lit when unit is ready to dispense cards

6
5VDC
7
NORMALLY OPENRESET SWITCH
8
COMMON
9
LIT BUTTON / LAMP

RESET & JAM SIGNAL

Enables a lamp to be lit when card has not been dispensed. If a card jams, or fraud is experiences, a flashing output will occur.

10
5VDC
11
LIT BUTTON / LAMPDISPENSER EMPTY SIGNAL
12
5VDC

  • No labels