3275 LaundryCard Reader Install Guide

ERROR: Equipment ID 3275 does not exist.

Install Mounting Hardware

 I-M0020

Part #: C-0015

Desc 1: Label

Desc 2: Reader Cover Label

   Qty: 1

Part #: C-0031

Desc 1: Label

Desc 2: Dexter Instruction Panel

   Qty: 1

Part #: C-0133

Desc 1: Standoff

Desc 2: 8-32" x 1-1/2" - Hex

   Qty: 2

Part #: C-0140

Desc 1: Screw

Desc 2: 8-32 x 3/4" - Cap

   Qty: 2

Part #: C-0906

Desc 1: Spacer Plate

Desc 2: 5 1/2" x 4 3/8"

   Qty: 1

Part #: C-0936

Desc 1: Vault Mount Bracket

Desc 2:

   Qty: 1

Part #: C-0963

Desc 1: Drop Cover

Desc 2: 2-3/8" x 4-5/8" - Black

   Qty: 1

Part #: C-1062

Desc 1: Nut

Desc 2: 4-40 - Kep

   Qty: 4

  1. Remove existing coin box.

  2. Bend the side tabs of the C-0936 Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  3. Attach the C-0133 Standoffs to the Bracket.

  4. Place the C-0906 spacer between the reader and the machine's panel.

  5. Remove any existing coin drop.

  6. Mount the C-0963 Drop Cover using C-1062 Kep Nuts.

  7. Affix C-0031 Label to the C-0963 Drop Cover.

Connect Machine Interface Harness

 I-T0040

Part #: C-5256

Desc 1: Machine Start Harns (pulse)

Desc 2: 20" - Male taps, Rq. Female

   Qty: 1

  1. Connect the C-5256 Machine Start Harness to the Coin 1 terminal connections previously connected to the micro switch on the coin drop.

Connect and Mount Reader

  1. Feed remaining harness ends through mounting bracket.

  2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  4. Secure the LaundryCard reader to the bracket using included hardware.

Machine Configuration

TODO