0262 F1 Reader Install Guide

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Front Load Washer
Manufacturer: Maytag
Make: Maytag
Model Length: Not Set

Associated Models


MHN30PDAWW
MHN30PDBWW
MHN30PDC
MHN30PDCWW
MHN30PRBWW
MHN30PRCWW

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0142

Part #: C-5800

Desc 1: F1 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0085

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-0303

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-5027

Desc 1: Label

Desc 2: Credit Card Logo

   Qty: 1

Part #: C-5771

Desc 1: Metercase Bracket

Desc 2: Coin Drop Ready Machines

   Qty: 1

  1. Remove coin drop and coin box.

  2. Insert the C-5771 Metercase Bracket over the front of the metercase. Attach using the C-0303 Topload Mounting Bolt from the inside of the metercase.

  3. Optional: Apply the C-5027 Label on or near the card reader for any accepted credit card issuers.

Connect Power

 I-P0003

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap the incoming AC power wires using the C-5101 Spade Taps.

    1. For 120v models: L1, N, and Ground wires

  2. Connect the three wires from the C-5210 Power Adapter Harness to the C-5101 Spade Taps.

    1. Connect the Blue wire to the L1 tap.

    2. Connect the Brown wire to the N tap.

    3. Connect the Green/Yellow wire to the Ground tap.

  3. Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connector on the C-5602R1 Power Converter.

  4. Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connector on the C-5500 Power Extension Harness.

  5. Run the C-5500 Power Extension Harness to the reader mounting location.

Connect Coin Sense Harness

 I-S0020

Part #: C-5362

Desc 1: Coin Sense Harness

Desc 2: MLG

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-5362 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0090

Part #: C-5364

Desc 1: Machine Start Harness

Desc 2: Maytag MFR

   Qty: 1

Part #: C-0126-MLV-EXT15

Desc 1: Extension Harness

Desc 2: Compass

   Qty: 1

  1. Connect the C-5364 Machine Start Harness to the AA3 (Debit) connector on the Machine Control Assembly.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.

  2. Connect the free end of the C-5364 Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. (Coin and Card Installation Only) Connect the free end of the C-5362 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  4. Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

Machine Configuration