3638 F1 Reader Install Guide
Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Overview
Equipment Details
Type: Washer Extractor
Manufacturer: Alliance
Make: Huebsch
Model Length: 18
Associated Models
HYT020VX0HXUB0C0BA
HYT020VX0HXUB0C0FQ
HYT030VCAHXUB0C0BA
HYT030VX0HXUB0C0BA
HYT030VX0HXUB0C0FQ
HYT030VX0HXUB0X0BA
HYT040VCAHXUB0C0BA
HYT040VCAHXUB0E0BA
HYT040VX0HXUB0E0FQ
HYT055VCAHXUB0E0BA
HYT055VCAHXUB0X0BA
HYT055VX0HXUB0E0BA
HYT055VX0HXUB0E0FQ
HYT070VCAHXUB0C0BA
HYT070VCAHXUB0E0BA
HYT070VX0HXUB0E0FQ
SYT020VCAHXUB0C0BA
SYT020VX0HXUB0C0BA
SYT030VCAHXUB0C0FQ
SYT040VCAHXUB0E0BA
SYT040VX0HXUB0E0BA
SYT055VX0HXUB0E0BA
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the C-5265 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the C-5360 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-5500 Power Harness to port 4.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
Machine Configuration
Singlevend - Coin Pulse
Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
Machine Settings
Liquid Soap Supply: Enabled
Payment Settings:
Enable Types: Disable all payment types
Coin Options: Single
Coin 1 Value: Intended Vend Price
Coin 2 Value: Intended Vend Price
Serial Payment System: Disabled
On the FasCard Admin site, create a SingleVend equipment type with the following settings:
Mode: Simple
Pulse Length: 1000
Pulse Interval: 250
Pulse Type: Relay
Sensor Input: Required Off
Show Remaining Time: Disabled
Cycle Time: 600 Seconds
# Pulses: 1