3638 F1 Reader Install Guide
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the C-5265 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the C-5360 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-5500 Power Harness to port 4.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
Machine Configuration
Singlevend - Coin Pulse
Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
Machine Settings
Liquid Soap Supply: Enabled
Payment Settings:
Enable Types: Disable all payment types
Coin Options: Single
Coin 1 Value: Intended Vend Price
Coin 2 Value: Intended Vend Price
Serial Payment System: Disabled
On the FasCard Admin site, create a SingleVend equipment type with the following settings:
Mode: Simple
Pulse Length: 1000
Pulse Interval: 250
Pulse Type: Relay
Sensor Input: Required Off
Show Remaining Time: Disabled
Cycle Time: 600 Seconds
# Pulses: 1