Overview
Equipment Details
Type: Stack Washer/Dryer
Manufacturer: Dexter
Make: Dexter
Model Length: 22
Washer Portion of Stack Washer/Dryer.
Associated Models
WCS350XA12EC3XSWBCSUSA
WCS450XA12EC2XSWBCSUSA
WCS450XC12EC4XSWBCSUSA
WCS750XA12EC2XSWBCSUSA
WCS750XC12EC4XSWBCSUSA
Installation
Install Mounting Hardware
Connect Power
I-P0025
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500-115
Desc 1: Power Extension Harness
Desc 2: 115"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5336 Power Adapter Harness to the power distribution terminal block inside the machine.
Use C-5101 Spade Tap on a L1 and L2 power wire.
Connect the C-5336 Power Adapter Harness. Blue wire to L1 and Brown to L2.
Connect the Green/Yellow wire to the ground screw.
Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.
Connect the C-5500-115 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0034
Part #: C-6258
Desc 1: Coin Sense Harness (SA)
Desc 2: WCAD
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6258 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
C-Series (1.5) | SingleVend (Relay) / 55ms | Dexter C-Series Washer Extractor |