Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Tumble Dryer (Stack)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 16 to 18

For ACA control equipped models with an "X" as the 8th character, they will need to clarify if they will be using an electronic coin drop that requires the H10 accessory power connection. If so, they will need the "ACA Controls with Electronic Coin Drop" power kit instead of the "H10 Accessory Power" kit.

Associated Models


HTT30LNY0RXS6NC000
HTT30NBCANBG3N0000
HTT30NBCANBG3W0000
HTT30NBCANXG3N0000
HTT30NBCARBG5W0000
HTT30NBCARXC5NC000
HTT30NBCARXG5W0000
HTT30NBCARXS5NC000
HTT30NBXANBG3N0000
HTT30NBY0NBG3N0000
HTT30NBY0NBS3NC000
HTT30NBY0NXG3N0000
HTT30NBY0NXG3W0000
HTT30NBY0RBG5W0000
HTT30NBY0RXS5NC000
HTT30NBYANBG3N0000
HTT30NNC0NBG3W00A0
HTT30NNC0NBS3NC0C0
HTT30NNCANBG3N0000
HTT30NNCANBG3NC0C0
HTT30NNCANBG3W0000
HTT30NNCANXG3N0000
HTT30NNCANXG3N00A0
HTT30NNCANXG3N00C0
HTT30NNCANXG3NC0C0
HTT30NNCARB6W000
HTT30NNCARBG3NC0C0
HTT30NNCARBG6W0000
HTT30NNCARBS6NC000
HTT30NNCARBS6NC0A0
HTT30NNCARXG6W0000
HTT30NNCARXS6NC000
HTT30NNCARXS6NC0A0
HTT30NNNARBS6NC000
HTT30NNX0RXS6NC000
HTT30NNY0NBG3N0000
HTT30NNY0NBS3NC0C0
HTT30NNY0NXG3N0000
HTT30NNY0RBG6W0000
HTT30NNY0RBS6NC000
HTT30NNY0RXG6W0000
HTT30NNY0RXS6NC000
HTT30NVCARBS6NC000
HTT30NVCARXS6NC000
HTT30NVCARXS6NCC00
HTT30NVY0RBS6NC000
HTT30NVY0RXS6NC000
HTT30NWCANBG3N0000
HTT30NWCANBG3N00A0
HTT30NWCANBG3N00C0
HTT30NWCANBG3NC000
HTT30NWCANBG3NC0A0
HTT30NWCANBG3NC0C0
HTT30NWCANBG3NCOCO
HTT30NWCANBG3W0000
HTT30NWCANBJ3N00C0
HTT30NWCANXG3N00A0
HTT30NWCANXG3NC0C0
HTT30NWCARB85NC000
HTT30NWCARBS5NC000
HTT30NWCARBS5NC0A0
HTT30NWCARBS6NC000
HTT30NWCARBS6NC0A0
HTT30NWCARXS5NC0A0
HTT30NWCARXS6NC000
HTT30NWCARXS6NC0A0
HTT30NWP0RBS5NC000
HTT30NWY0NBG3N0000
HTT30NWY0NBG3N00A0
HTT30NWY0NBG3N00C0
HTT30NWY0NBG3NC0A0
HTT30NWY0NBG3NC0C0
HTT30NWY0NBS3N0000
HTT30NWY0NDG3NC0A0
HTT30NWY0NXG3N00A0
HTT30NWY0NXG3NC0A0
HTT30NWY0RBG5W0000
HTT30NWY0RBS5NC000
HTT30NWY0RBS5NC0C0
HTT30NWY0RBS6NC000
HTT30NWY0RBS6NC0A0
HTT30NWY0RXS5NC000
HTT30NWY0RXS5NC0A0
HTT30NWY0RXS5NC0C0
HTT30NWY0RXS6NC000
HTT30NWY0RXS6NC0A0
HTT45LNY0RXS6NC000
HTT45LWCARX35NC000
HTT45LWCARX85NC000
HTT45LWCARXG5W0000
HTT45LWCARXS5NC000
HTT45NBCANXG3N0000
HTT45NBCANXG3W0000
HTT45NBCANXS3N0000
HTT45NBCARXG5W0000
HTT45NBCARXS5NC000
HTT45NBY0NBS3NC000
HTT45NBY0NXG3N0000
HTT45NBY0NXG3W0000
HTT45NBY0NXS3NC000
HTT45NBY0RXS5NC000
HTT45NBYARXS6NC000
HTT45NNC0NBB3N00
HTT45NNC0NXG3W00A0
HTT45NNC0NXS3NC0C0
HTT45NNCANXG0NC000
HTT45NNCANXG3N0000
HTT45NNCANXG3N00A0
HTT45NNCANXG3NC0C0
HTT45NNCANXG3W0000
HTT45NNCARBS6NC000
HTT45NNCARRS5NC000
HTT45NNCARXG6W0000
HTT45NNCARXS6NC000
HTT45NNCARXS6NC0A0
HTT45NNN0RXA6W0000
HTT45NNX0RXS6NC000
HTT45NNY0NXG3N0000
HTT45NNY0NXS3NC0C0
HTT45NNY0RBS6NC000
HTT45NNY0RX56NC000
HTT45NNY0RXG6W0000
HTT45NNY0RXS6NC000
HTT45NNY0RXS6NC0A0
HTT45NVC0RXS5NC000
HTT45NVCARX85NC000
HTT45NVCARXS5NC000
HTT45NVCARXS6NC000
HTT45NVCARXS6NCK00
HTT45NVL0RXS5NC000
HTT45NVP0RXS5NC000
HTT45NVX0RXS5NC000
HTT45NVX0RXS6NC000
HTT45NVY0RXS6NC000
HTT45NWC0NXG0NC0C0
HTT45NWCANXG3N0000
HTT45NWCANXG3N00A0
HTT45NWCANXG3N00C0
HTT45NWCANXG3NC000
HTT45NWCANXG3NC0A0
HTT45NWCANXG3NC0C0
HTT45NWCANXG3W0000
HTT45NWCARBS5NC0A0
HTT45NWCARX56NC000
HTT45NWCARX86NC000
HTT45NWCARXF6NC0A0
HTT45NWCARXS3NC000
HTT45NWCARXS500000
HTT45NWCARXS5NC000
HTT45NWCARXS5NC0A0
HTT45NWCARXS6N0CA0
HTT45NWCARXS6NC000
HTT45NWCARXS6NC0A0
HTT45NWCARXS6NCA00
HTT45NWL0RXS5NC000
HTT45NWP0RBS5NC000
HTT45NWP0RXS5NC000
HTT45NWP0RXS6NC000
HTT45NWX0RXS5NC0A0
HTT45NWY0NBG3NC0C0
HTT45NWY0NX53NC0C0
HTT45NWY0NX63NC000
HTT45NWY0NXG0NC0C0
HTT45NWY0NXG3N0000
HTT45NWY0NXG3N00A0
HTT45NWY0NXG3N00C0
HTT45NWY0NXG3NC000
HTT45NWY0NXG3NC0A0
HTT45NWY0NXG3NC0C0
HTT45NWY0NXG3W0000
HTT45NWY0NXG5NC0A0
HTT45NWY0NXS3N0000
HTT45NWY0NXS3NC000
HTT45NWY0NXS3NC0C0
HTT45NWY0NXZ3NC0A0
HTT45NWY0RBS5NC0C0
HTT45NWY0RXG3NC0C0
HTT45NWY0RXG5W0000
HTT45NWY0RXS4NC000
HTT45NWY0RXS5NC000
HTT45NWY0RXS5NC080
HTT45NWY0RXS5NC0A0
HTT45NWY0RXS5NC0C0
HTT45NWY0RXS6NC000
HTT45NWY0RXS6NC0A0
KTT30EBDANFS3WAA
KTT30LBCANBH3N00
KTT30LNY0RXH6N00
KTT30NBCANBH3N00
KTT30NBCANBH3N0000
KTT30NBCANXH3N00
KTT30NBCANXH3N0A00
KTT30NBCANXS3W00
KTT30NBCANXS3W0000
KTT30NBCARBH3W0000
KTT30NBCARD83W0000
KTT30NBCB2H2N000
KTT30NBCB2H2N001
KTT30NBY0NXH3N0000
KTT30NBY0RBG5W0000
KTT30NBYANBH3N00
KTT30NBYB2H2N000
KTT30NBYB2H2N001
KTT30NNCARBH3N00
KTT30NNCARBH3N0000
KTT30NNCARBH6N00
KTT30NNCARXH3N00
KTT30NNCARXH3N0000
KTT30NNCARXH6N00
KTT30NNCARXH6N0000
KTT30NNCARXH6W00
KTT30NNCARXH6W0000
KTT30NNN0NXH3W00
KTT30NNY0RB86N00
KTT30NNY0RB86N0000
KTT30NNY0RBH3N00
KTT30NNY0RBH3N0000
KTT30NNY0RBH6N00
KTT30NNY0RXH3N00
KTT30NNY0RXH6N00
KTT30NNY0RXH6N0000
KTT45LBCANXH3N00
KTT45NBCANX53N00
KTT45NBCANXH3N00
KTT45NBCANXH3N0000
KTT45NBCANXH3W00
KTT45NBCANXS3N00
KTT45NBCARXH3W00
KTT45NBCARXH6W00
KTT45NBCARXS3W00
KTT45NBCG2H2N000
KTT45NBY0NXH3N0000
KTT45NBY0RXH3W00
KTT45NBYG2H2N000
KTT45NBYG2H2W000
KTT45NBYG2H2W001
KTT45NNCANXS3W0000
KTT45NNCARBH6N00
KTT45NNCARXH3000
KTT45NNCARXH3N00
KTT45NNCARXH3N0000
KTT45NNCARXH6N00
KTT45NNCARXH6N0000
KTT45NNCARXH6W00
KTT45NNCARXH6W0000
KTT45NNCARXH6WAO
KTT45NNX0RXH6N00
KTT45NNX0RXH6N0000
KTT45NNY0NXH3N0000
KTT45NNY0RBH3N0000
KTT45NNY0RX86N00
KTT45NNY0RXH3N00
KTT45NNY0RXH3N0000
KTT45NNY0RXH6N00
KTT45NNY0RXH6N0000
PTT30NNCANBG3N0000
PTT45NNCANXG3G0000
PTT45NNCANXG3N0000
SGT30LBFANXG3W0000
STT30NBCANBG3N0000
STT30NBCANBG3W0000
STT30NBCANDG3N0000
STT30NBCANXG3N0000
STT30NBCANXG3W0000
STT30NBCARBG5W0000
STT30NBCARXG5W0000
STT30NBDANBG3W0000
STT30NBY0NBG3N0000
STT30NBY0NBG3W0000
STT30NBY0NXG3N0000
STT30NBY0NXG3W0000
STT30NNCANBG3N0000
STT30NNCANBG3W0000
STT30NNCANXG3N0000
STT30NNCARBG5W0000
STT30NNCARBG5W01
STT30NNCARBG6000
STT30NNCARBG600000
STT30NNCARBG6W0000
STT30NNCARBGW00000
STT30NNCARBS5NC000
STT30NNCARBS6NC000
STT30NNCARXG6W0000
STT30NNCARXS6NC000
STT30NNDANXG3N0000
STT30NNY0NXG3N0000
STT30NNY0RBG5W0000
STT30NNY0RBS5NC000
STT30NNY0RBS6NB000
STT30NNY0RBS6NC000
STT30NNY0RXG6W0000
STT30NNY0RXS5NC000
STT30NNY0RXS6NC000
STT30NVCANBH4NC000
STT30NVCANDH4NB000
STT30NVCARBH5NC000
STT30NVCARBS5NC000
STT30NVCARBS6NC000
STT30NVCARXS6NC000
STT30NVE0RBS6NC000
STT30NVX0RBS6NC000
STT30NVY0NBH4NC000
STT30NVY0RBS5NC000
STT30NVY0RBS6NC000
STT30NVY0RXS5NC000
STT30NVY0RXS6NC000
STT30NVY0RXS6NCC0P
STT30NWCANBG3N0000
STT30NWCANXG3N0000
STT30NWCANXG3W0000
STT30NWCARBF6NC000
STT30NWCARBS6NC000
STT30NWCARXS6NC000
STT30NWP0RXS6NC000
STT30NWX0NBG3N0000
STT30NWY0RBS6NC000
STT30NWY0RXS6NC000
STT45LNCARXG5W0000
STT45NBCANXG3N0000
STT45NBCANXG3W0000
STT45NBX0RXH5NC000
STT45NBY0NX63N0000
STT45NBY0NXG3N0000
STT45NBY0NXG3W0000
STT45NBY0RXG5W0000
STT45NNCANXG3N0000
STT45NNCANXG3W0000
STT45NNCANXG5N0000
STT45NNCANXS3W0000
STT45NNCARBS6NC000
STT45NNCARX55NC000
STT45NNCARX60000
STT45NNCARXG5W0000
STT45NNCARXG5W01
STT45NNCARXG6W0000
STT45NNCARXS5NC000
STT45NNCARXS6NC000
STT45NNDANXG3N0000
STT45NNY0NXG3N0000
STT45NNY0NXZ3N0000
STT45NNY0RBS5NC000
STT45NNY0RXG5W0000
STT45NNY0RXG6W0000
STT45NNY0RXS5NC000
STT45NNY0RXS6NC000
STT45NVCANXH4NC000
STT45NVCARX95NC000
STT45NVCARXH5NC000
STT45NVCARXS5N0000
STT45NVCARXS5NC000
STT45NVCARXS5NCAA0
STT45NVCARXS6NC000
STT45NVP0RXS6NC000
STT45NVX0NXH4NC000
STT45NVX0RBS6NC000
STT45NVX0RXH5NC000
STT45NVX0RXS5NC000
STT45NVX0RXS6NC000
STT45NVY0NXH4NC000
STT45NVY0RXH5NC000
STT45NVY0RXS5NC000
STT45NVY0RXS6NC000
STT45NWCANXG3N0000
STT45NWCANXG3NC000
STT45NWCANXH4NC000
STT45NWCARXG5W0000
STT45NWCARXS6NC000
STT45NWP0RXS6NC000
STT45NWY0NXG3N0000
STT45NWY0RXG6NC00P
STT45NWY0RXS6NC000
STT45NWYG2G20N02

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0109

Part #: C-1060

Desc 1: Screw - Build: TK

Desc 2: 8-32 x 3/8" - Zinc

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5710

Desc 1: Rubber Grommet

Desc 2: 3/4"

   Qty: 1

Part #: C-6970R1

Desc 1: F2, Bracket (revised)

Desc 2: Alliance Card Ready

   Qty: 1

  1. Install the C-6970 Alliance Mounting Bracket into the opening on the control panel for mounting card readers and coin drops.

  2. Attach the C-5414 F2 Mounting Bracket to the C-6970R1 Alliance Mounting Bracket and secure using the C-1060 Screws.

  3. Refer to F2/F3 FasCard Reader Mounting Guide for further instructions.

 I-M0107

Part #: C-0144

Desc 1: Screw

Desc 2: 8-32 x 2" - Flat

   Qty: 2

Part #: C-5710

Desc 1: Rubber Grommet

Desc 2: 3/4"

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

Part #: C-6936

Desc 1: F2, Sm Vault Mount Bracket

Desc 2:

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

  1. Remove existing coin box and coin drop.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.

  3. Bend the side tabs of the C-6936 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Place the C-5710 Rubber Grommet into the circular opening of the C-6936 Vault Bracket.

  5. Align the C-5414 F2 Mounting Bracket over the coin vault opening and then attach the to the C-6936 Vault Bracket using the (2) C-0144 screws.

  6. Apply C-5033 Label over coin drop opening.

 I-M0181

Part #: C-6976

Desc 1: F2 Quantum Touch Stk Dryer

Desc 2: Mount

   Qty: 1

Part #: C-1073

Desc 1: Nut

Desc 2: 10-24 - Kep

   Qty: 4

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. (Coin Model Only) Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.

  2. Remove factory payment device bay cover or card reader mounting plate.

  3. Place the C-6976 Quantum Touch Stk Dryer Mounting Bracket into the payment device opening and secure using the (4) C-107310-24 Hex Nut.

  4. Align the C-5414 F2 Mounting Bracket with the C-6976 Quantum Touch Stk Dryer Mounting Bracket and attach using the (2) C-5420 10-32 x 1/4" Screws.

Connect Power

 I-P0002

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 Power Adapter Harness (12VDC power) to the H10 connection on the Machine Control Assembly.

  2. Secure the green wire beneath the ground screw.

 I-P0008

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500-84

Desc 1: Power Extension Harness

Desc 2: 84"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602R1 Power Converter.

  3. Connect the C-5500-84 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0003

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Extras

 I-X0005

Part #: C-5240-144

Desc 1: Machine Start Harness

Desc 2: 144" for Alliance ACA

   Qty: 1

Part #: C-6250-144

Desc 1: Coin Sense Harness

Desc 2: 144" length

   Qty: 1

Part #: C-6401

Desc 1: Stack Add On Board - MLV

Desc 2: Serial / MultiVend

   Qty: 1

  1. Run C-5240-144 Machine Start Harness and C-6250-144 Coin Sense Harness to the second Machine Control Assembly.

  2. Connect C-5240-144 Machine Start Harness to the H3 connection and the C-6250-144 Coin Sense Harness to the Coin 1 connection on the second Machine Control Assembly.

  3. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.

    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.

    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

  4. Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.

  5. Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.

 I-X0011

Part #: C-6401

Desc 1: Stack Add On Board - MLV

Desc 2: Serial / MultiVend

   Qty: 1

Part #: C-5240-144

Desc 1: Machine Start Harness

Desc 2: 144" for Alliance ACA

   Qty: 1

Part #: C-0940

Desc 1: Vault Cover

Desc 2: 3-7/8" x 2-3/4"

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

  1. Install C-0940 Vault Cover into the coin vault for the secondary control.

  2. Run C-5240-144 Machine Start Harness to the second Machine Control Assembly.

  3. Connect C-5240-144 Machine Start Harness to the H3 connection on the second Machine Control Assembly.

  4. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.

    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.

    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

 I-X0013

Part #: C-6401

Desc 1: Stack Add On Board - MLV

Desc 2: Serial / MultiVend

   Qty: 1

Part #: C-5240-144

Desc 1: Machine Start Harness

Desc 2: 144" for Alliance ACA

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

  1. Run C-5240-144 Machine Start Harness to the second Machine Control Assembly.

  2. Connect C-5240-144 Machine Start Harness to the H3 connection on the second Machine Control Assembly.

  3. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.

    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.

    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

 I-X0023

Part #: C-6411

Desc 1: F3, MLV Stack Add On Dongle

Desc 2: Serial / MultiVend

   Qty: 1

Part #: C-5240-144

Desc 1: Machine Start Harness

Desc 2: 144" for Alliance ACA

   Qty: 1

Part #: C-6250-144

Desc 1: Coin Sense Harness

Desc 2: 144" length

   Qty: 1

The following steps assume the start and coin sense harnesses are already connected to the upper pocket control.

  1. Locate area to mount C-6411 Serial Stack Add-On Board.

    1. Must be close enough to reader mounting location to connect the harness to.

    2. Must be on a surface that does not received direct exposure from any heating elements (If applicable.)

  2. Clean mounting location to remove any dust and residue if needed.

  3. Remove the sticker from the back of the C-6411 Serial Stack Add-On Board to expose the adhesive and apply to the mounting location.

  4. Connect the white, 7-pin connector from the C-5240-144 to the H3 connection on the lower pocket's Machine Control Assembly.

  5. Connect the the clear, 3-pin circuit board end from the C-6250-144 Coin Sense Harness to the lower pocket's Coin Drop.

 I-X0024

Part #: C-6411

Desc 1: F3, MLV Stack Add On Dongle

Desc 2: Serial / MultiVend

   Qty: 1

Part #: C-5240-144

Desc 1: Machine Start Harness

Desc 2: 144" for Alliance ACA

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

The following steps assume the start and coin sense harnesses are already connected to the upper pocket control.

  1. Locate area to mount C-6411 Serial Stack Add-On Board.

    1. Must be close enough to reader mounting location to connect the harness to.

    2. Must be on a surface that does not received direct exposure from any heating elements (If applicable.)

  2. Clean mounting location to remove any dust and residue if needed.

  3. Remove the sticker from the back of the C-6411 Serial Stack Add-On Board to expose the adhesive and apply to the mounting location.

  4. Connect the white, 7-pin connector from the C-5240-144 to the H3 connection on the lower pocket's Machine Control Assembly.

  5. Optional: Apply C-5033 Label over the card reader opening for the lower pocket control.

 I-X0024

Part #: C-6411

Desc 1: F3, MLV Stack Add On Dongle

Desc 2: Serial / MultiVend

   Qty: 1

Part #: C-5240-144

Desc 1: Machine Start Harness

Desc 2: 144" for Alliance ACA

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

The following steps assume the start and coin sense harnesses are already connected to the upper pocket control.

  1. Locate area to mount C-6411 Serial Stack Add-On Board.

    1. Must be close enough to reader mounting location to connect the harness to.

    2. Must be on a surface that does not received direct exposure from any heating elements (If applicable.)

  2. Clean mounting location to remove any dust and residue if needed.

  3. Remove the sticker from the back of the C-6411 Serial Stack Add-On Board to expose the adhesive and apply to the mounting location.

  4. Connect the white, 7-pin connector from the C-5240-144 to the H3 connection on the lower pocket's Machine Control Assembly.

  5. Optional:

    1. Apply C-5033 Label over the card reader opening for the lower pocket control.

    2. Install the C-0940 Vault Cover into the coin vault opening by extending the inner wings of the cover outwards. Then insert into the coin vault opening until the wings lock into place.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

ACA Controls

  1. Locate the dip switch on the back of the machine's control board.

  2. Set dip switch 3 to the ON position. 

  3. Leave all other dip switches as is.

CCI Software Configuration

Machine ControlPulseSerial
Dual Digital Timer (OPL)*NOT SUPPORTED**NOT SUPPORTED*
EVO7S*NOT SUPPORTED**NOT SUPPORTED*
Galaxy (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Galaxy 600 (A2)SingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A2 - Galaxy 600
MDC II (A1)SingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A1 - MDC II
Micro (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Micro Control VendSingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A4 - Quantum+
M-Series (OPL)*NOT SUPPORTED**NOT SUPPORTED*
OPTimum (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Quantum Gold (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Quantum Touch (Midas)SingleVend (MLV+) / 80msAlliance Quantum Touch Tumbler Dryer
Quantum+ (A4)SingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A4 - Quantum+
UniLinc (OPL)*NOT SUPPORTED**NOT SUPPORTED*
XQ*NOT SUPPORTED**NOT SUPPORTED*

  • No labels