Skip to end of metadata
Go to start of metadata
Overview
Equipment Details
Type: Washer
Manufacturer: Alliance
Make: IPSO
Model Length: 5
Associated Models
WE181
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
I-M0061
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-0031
Desc 1: Label
Desc 2: Dexter Instruction Panel
Qty: 1
Part #: C-0144
Desc 1: Screw
Desc 2: 8-32 x 2" - Flat
Qty: 2
Part #: C-0905
Desc 1: Drop Cover
Desc 2: 2-3/8" x 4-5/8"
Qty: 1
Part #: C-0960
Desc 1: Mounting Bracket
Desc 2: IPSO
Qty: 1
Part #: C-0961
Desc 1: Jam ring
Desc 2: IPSO
Qty: 1
Part #: C-1043
Desc 1: Screw
Desc 2: 8-32 x 1-3/4" - Flat
Qty: 2
Install the C-0961 Jam Ring into the coin vault. The Jam Ring should be installed into the coin vault so that it is within 1.5" of front panel of the machine to allow the mounting bracket to be attached.
To install the Jam Ring insert the ring so the small portion is on the bottom. Insert at an angle, so the top of the Jam Ring is inserted first. Once the ring is in position, pull the top of the Jam Ring towards the front of the machine until it locks into place.
Using the C-0144 Screws, attach the C-0960 Mounting Bracket to the C-0961 Jam Ring.
Secure reader to C-0960 Mounting Bracket using C-1043 Screw.
Install the C-0905 Drop Cover where the coin drop was installed. Secure using the original hardware.
Apply C-0031 Label over the C-0905 Drop Cover.
I-M0133
Part #: C-0905
Desc 1: Drop Cover
Desc 2: 2-3/8" x 4-5/8"
Qty: 1
Part #: C-0961
Desc 1: Jam ring
Desc 2: IPSO
Qty: 1
Part #: C-5751
Desc 1: Screw
Desc 2: 8-32 x 2-1/2" - Flat
Qty: 2
Part #: C-6960
Desc 1: IPSO Mounting Brkt
Desc 2: Powder coated black
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Install the C-0961 Jam Ring into the coin vault. The Jam Ring should be installed into the coin vault so that it is within 1.5" of front panel of the machine to allow the mounting bracket to be attached.
To install the Jam Ring insert the ring so the small portion is on the bottom. Insert at an angle, so the top of the Jam Ring is inserted first. Once the ring is in position, pull the top of the Jam Ring towards the front of the machine until it locks into place.
Using the C-5751 Screws, attach the C-6960 Mounting Bracket to the C-0961 Jam Ring.
Attach the C-5414 Standard Mounting Bracket to the C-6960 Mounting Bracket using the C-5420 Screws.
I-M0142
Part #: C-5800
Desc 1: F1 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F1 Reader Mounting Guide for further instructions.
I-M0216
Part #: C-6802
Desc 1: FLEX RF Reader Mounting Kit
Desc 2:
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
Instructions do not exist for Kit I-M0249
Connect Power
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0004
Part #: C-5253
Desc 1: Coin Sense Harness
Desc 2: 28"
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5253 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0031
Part #: C-6253
Desc 1: Coin Sense Harness
Desc 2: 28"
Qty: 1
Disconnect the factory harness from the micro switch tabs on the Coin Drop.
Connect the C-6253 Coin Sense Harness to the micro switch tabs in any pairing.
Connect Machine Interface Harness
I-T0016
Part #: C-0113
Desc 1: Machine Start Harness
Desc 2: 2-Wire Harness
Qty: 1
Remove the harness connected to the microswitch mounted to the coin drop. Connect the C-0113 Machine Start Harness to the harness previously connected to the microswitch.
I-T0040
Part #: C-5256
Desc 1: Machine Start Harns (pulse)
Desc 2: 20" - Male taps, Rq. Female
Qty: 1
Connect the C-5256 Machine Start Harness to the harness previously connected to the micro switch on the coin drop/slide.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
TODO
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Micro 20 | SingleVend (Relay) / 500ms | *NOT SUPPORTED* |