Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Front Load Washer
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15

Associated Models


BFNBCFSG111TN01
BFNBCFSP112TW01
BFNBEFSP1110W01
BFNBEFSP111CW01
HFNBCFSG111TN01
HFNBCFSG112TN01
HFNBCFSG112TQ01
HFNBCFSP111TN01
HFNBCFSP112TW01
HFNBCRSP112TW01
SFNBCFSP112TW01
SFNBCRSP112TW01
SFNBXFSP112TW01
SFNBYRSP112TW01
SFNCCFSP111TW01
SFNLCF8G111TN01
SFNLCFSG111TN01
SFNLCFSG111TW01
SFNLCFSP111TN01
SFNLCFSP111TQ01
SFNLCFSP111TW01
SFNLGFSG111TN01
SFNLYFSG111TN01
SFNNCF8G1127N01
SFNNCFAG112TN01
SFNNCFSD112TN01
SFNNCFSG112TN01
SFNNCFSG112TW01
SFNNXFSP112TN01
SFNWCFSG112TN01
SFNWCFSG112TN11
SFNWCFSG172TN11
SFNWYFSG112TN01
SFNWYFSG112TW01

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0136

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0141

Part #: C-1059

Desc 1: Nut

Desc 2: 10-32 - Kep

   Qty: 2

Part #: C-1070-W

Desc 1: Washer - Build: XCH

Desc 2: 1/4" x 1" O.D.

   Qty: 2

Part #: C-6760

Desc 1: Metercase Bracket

Desc 2: Coin Slide Ready Machine

   Qty: 1

Part #: C-5760-A

Desc 1: Alliance Adapter Bracket

Desc 2: Mounts C-5760 to MeterCase

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin drop.

  2. Attach C-5760-A Alliance Adapter Bracket to C-6760 Metercase Bracket.

  3. Attach the C-5414 Mounting Bracket to C-6760 Metercase Bracket using the (2) C-5420 10-32 x 1/4 Pan Screws.

  4. Mount C-6760 Metercase Bracket into the front of the metercase, inserting the two studs through the coin slot openings.

    1. Secure to the metercase using (2) C-1059 Keps Nuts and (2) C-1070-W Washers.

Connect Power

 I-P0003

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5210 Power Adapter Harness to the power distribution panel inside the machine.

    1. 120vac: Connect the blue wire to L1 and the brown wire to N.

    2. 240vac: Connect the blue wire to L1 and the brown wire to L2.

    3. Secure the green wire to the ground wire.

  2. Connect the opposite end of the C-5210 Power Adapter Harness to the C-5602R1 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0012

Part #: C-0110-TOP

Desc 1: Machine Start Harness

Desc 2: 36" - Alliance Pre-ACA

   Qty: 1

Part #: C-0110-CP

Desc 1: Jumper Plug

Desc 2: Enables card mode on pre-ACA

   Qty: 1

  1. Connect the C-0110-TOP Machine Start Harness to the machine control assembly at:

    1. H5 for MDC controls.

    2. H4 for Centurion controls.

  2. (Serial Communication Setup Only) Replace the existing Alliance Jumper Plug with C-0110-CP Jumper Plug at:

    1. H2 for MDC controls.

    2. H6 for Centurion controls

Connect and Mount Reader

Machine Configuration

MDC Controls

  1. Power off the machine.

  2. Connect the C-0110-CP Jumper Plug to the H2 connection on the Machine Control Assembly.

  3. Power on the machine.

Centurion Quantum Gold TLW Controls

  1. Power off the machine.

  2. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.

  3. Power on the machine.

CCI Software Configuration

Machine ControlPulseSerial
MDC (Vended)SingleVend (MLV+) / 80msAlliance MDC Front Load Washer
Quantum Gold (C4)SingleVend (MLV+) / 80msAlliance Centurion Front Load Washer C4 - Quantum Gold