Skip to end of banner
Go to start of banner

3599 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

« Previous Version 4 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Equipment Details

Type: Small Dryer (Stack)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15

On this page

Associated Models

SSGNCFGW113TW01

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0104 (Universal, Rubber Grommet)
Readers: F2,FLEX,L2,F3
Install Type: Coin and Card

Part #: C-5710

Desc 1: Rubber Grommet

Desc 2: 3/4"

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0136 (Universal)
Readers: F2,FLEX,L2,F3
Install Type: Card Only

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Remove existing coin box.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.

  3. Bend the side tabs of the C-0941 Vault Cover outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Place the C-6700-TEMP Drill Template on the desired mounting location.

  5. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  6. Refer to FasCard Mounting Guide for further instructions.

 I-M0139 (Alliance, Front Control, Large Vault)
Readers: F2,FLEX,L2,F3
Install Type: Card Only

Part #: C-0941

Desc 1: Vault Cover

Desc 2: 3-7/8" x 3-1/2"

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Connect Power

 I-P0002 (C-6204-40)
Readers: F1,F2,FLEX,L2,F3,FLEX RF
Install Type: [ANY]

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the machine control assembly.

    1. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-6204-40 Power Adapter Harness (3-pin molex) to the F2 reader.

Connect Coin Sense Harness

 I-S0027 (C-6250)
Readers: F2,FLEX,L2,F3,FLEX RF
Install Type: Coin and Card

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0003 (C-5240)
Readers: [ANY]
Install Type: [ANY]

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Extras

 I-X0008 (Alliance, Stack Add-On, C-5240, 40")
Readers: F2,FLEX,L2
Install Type: Coin and Card

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: can use C-5240-144

   Qty: 1

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: can use C-6250-144

   Qty: 1

Part #: C-6401

Desc 1: Stack Add On Board - MLV

Desc 2: Serial / MultiVend

   Qty: 1

  1. Run C-5240 Machine Start Harness and C-6250 Coin Sense Harness to the second Machine Control Assembly.

  2. Connect C-5240 Machine Start Harness to the H3 connection and the C-6250 Coin Sense Harness to the Coin 1 connection on the second Machine Control Assembly.

  3. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.

    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.

    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

  4. Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.

  5. Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.

Instructions do not exist for Kit I-X0020

Instructions do not exist for Kit I-X0029

Instructions do not exist for Kit I-X0021

Instructions do not exist for Kit I-X0030

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

Unable to decodeSymmetric JWT token: Error: Signature verification failed for input: eyJ0eXAiOiJKV1QiLCJhbGciOiJIUzI1NiJ9.eyJxc2giOiI4NTRhMWEyNGMwOTZhM2I4N2YwYTNiODMxYjBkMzIxNzMzOGQwMTI0YmEyNmUyNjg1NDVmMjlmNWZiMDZlOTBkIiwiaXNzIjoiMThkY2NkY2YtMjM2YS0zZjdkLWE1YTItMGU2YzUxYzUwYTY1IiwiY29udGV4dCI6e30sImV4cCI6MTc0MDc1ODI3MCwiaWF0IjoxNzQwNzU4MDkwfQ with method sha256

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.

  • No labels