Overview
Equipment Details
Type: Washer
Manufacturer: Maytag
Make: Maytag
Model Length: 10 to 12
Associated Models
MYR20PDA23
MYR20PDT00
MYR20PDT0000
MYR20PDW0000
MYR30PDT0000
MYR30PDW0000
MYR30PDWATS
MYR30PRU0000
MYR30PRW0000
MYR40PDT0000
MYR40PRT0000
MYR55PDCTS
MYR55PDT00
MYR55PDT0000
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
I-M0152
Part #: C-0913
Desc 1: Drop Cover
Desc 2: Maytag Stack Dryer
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Part #: C-1062
Desc 1: Nut
Desc 2: 4-40 - Kep
Qty: 4
Part #: C-6936
Desc 1: F2, Sm Vault Mount Bracket
Desc 2:
Qty: 1
Part #: C-5751
Desc 1: Screw
Desc 2: 8-32 x 2-1/2" - Flat
Qty: 2
Remove coin drop and coin box.
Spread wings on C-6936 Vault Mount Bracket and insert into the coin vault.
Attach the C-5414 Standard Bracket to the C-6936 Vault Mount Bracket using the C-5751 Screws.
Insert the C-0913 Coin Drop Cover where the coin drop was originally installed. Secure with the C-1062 Kep Nuts.
I-M0185
Part #: C-6918
Desc 1: Mounting Bracket FasCard
Desc 2: (3 hole pattern)
Qty: 1
Part #: C-1066
Desc 1: Nut
Desc 2: M3.5 - Kep
Qty: 4
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove factory card reader interface bracket.
Attach C-5414 Reader Bracket to the C-6918 Mounting Bracket using (2) C-5420 10-32 x 1/4" Pan Screw.
Install the C-6918 Mounting Bracket in the payment device opening and secure using the (2) C-1062 Keps Nuts.
Run all reader harnesses through the center hole in the C-6918 Mounting Bracket.
Instructions do not exist for Kit I-M0197
Instructions do not exist for Kit I-M0198
I-M0216
Part #: C-6802
Desc 1: FLEX RF Reader Mounting Kit
Desc 2:
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
Instructions do not exist for Kit I-M0258
Instructions do not exist for Kit I-M0277
Connect Power
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Use the C-5101 Spade Taps on the incoming power.
Tap the L1 wire.
Tap the N / L2 wire.
Tap the Ground wire.
Take the C-5210 Power Adapter Harness and connect the red tab connectors to the following wires:
Connect the blue wire to the L1 wire.
Connect the brown wire to the N / L2 wire.
Connect the green/yellow wire to the Ground wire.
Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connection on the C-5602R1 Power Converter.
Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connection on the C-5500 Power Extension Harness.
Connect Coin Sense Harness
Connect Machine Interface Harness
I-T0088
Part #: C-5370
Desc 1: Machine Start Harness
Desc 2: MayTag 8pin
Qty: 1
Connect the C-5370 Machine Start Harness to the 8-pin J6 harness connection accessible near the coin drop.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
Enter Service Mode and navigate to J option.
Set option to J.d.
Exit Service Mode.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Gen1 | SingleVend (MLV+) / 24ms | *NOT SUPPORTED* |