This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Tumble Dryer (Single)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 18

Associated Models

HT055NVCARBS6NC000
HT075LVC0RXS5NC000
HT075LVP0RXS5NC000
HT075LVX0RXS5NC000
HT075NVCARBS5NC000
HT075NVCARBS6NC000
HT075NVCARXS5NC000
HT075NVCARXS6NC000
HT075NVCARXS6NCC00
HT075NVL0RBS5NC000
HT075NVY0RXS6NC000
ST030NVCANBH4NC000
ST055NVCARBS5NC000
ST055NVCARBS6NC000
ST055NVCARXS60BA00
ST055NVEARBS4NC000
ST055NVY0RBS6NC000
ST075NVCANBH4NC000
ST075NVCANBS4NC000
ST075NVCARBH5NC000
ST075NVCARBS5NC000
ST075NVCARBS6NC000
ST075NVCARXS6NC000
ST075NVP0RXS6NC000
ST075NVY0RBS6NC000
ST075NVYANBS4NC000

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to Touchscreen Reader Mounting Guide (F2 & F3) for further instructions.

 I-M0176

Part #: C-6965

Desc 1: F2 Quantum Touch Bracket

Desc 2:

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

  1. Disconnect wires connected to vault service switch and bridge connection using C-5365 Bypass Harness.
  2. Remove the front control Panel and pull panel away from machine exposing the factory plate / Coin Drop

  3. Loosen the two (2) left retaining screws (Green) and remove the remaining screws on the bracket (Blue) and slide the bracket off the machine.
  4. Slide the C-6965 QT Mounting Bracket onto the loose screws and tighten. Add remaining screws to the corresponding holes on the bracket and tighten.

  5. Re-secure the front panel to the machine.
  6. Attach the C-5414 Reader Bracket to the C-6965 QT Mounting Bracket using C-5702 Chase Nipple and C-5703 Nut.

  7. Feed all reader harnesses through the center hole.

Connect Power

 I-P0002

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 Power Adapter Harness to the H10 connection on the machine control board.

  2. Secure the green wire beneath the ground screw.

  3. Connect the opposite end of the C-6204-40 Power Adapter Harness (3-pin molex) into the back of the F1 Reader.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0003

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.
  1. Feed remaining harness ends through the mounting hole as described in the Touchscreen Reader Mounting Guide (F2 & F3).
  2. Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
  3. Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-6204-40 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the Touchscreen Reader Mounting Guide (F2 & F3).