Skip to end of metadata
Go to start of metadata
Overview
Equipment Details
Type: Tumble Dryer (Stack)
Manufacturer: ADC
Make: Maytag
Model Length: 10
Associated Models
MLG45PDBDS
MLG45PDBWS
MLG45PDBWW
MLG45PDBWW20
MLG45PDCWS
MLG45PDCWW
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
I-S0019
Part #: C-5361
Desc 1: Coin Sense Harness
Desc 2: Male taps, Rq. Female
Qty: 1
Part #: C-5260
Desc 1: Wire Tap Bridge
Desc 2: 18-16 AWG
Qty: 2
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Disconnect the Coin Drop from the Machine Control Assembly.
This harness must remain disconnected for FasCard to function properly. Reconnecting this harness after installation will damage FasCard reader. Technical Support recommends taping off these connections.
Bridge the solid Red and solid Blue wires coming from the coin eye sensor using the C-5260 Wire Tap Bridge.
Bridge the Blue/Silver and solid Purple wires going to the machine control assembly using the C-5260 Wire Tap Bridge.
Tap the Red, White, and White/Blue wires with the C-5101 Spade Taps provided.
Connect the C-5361 Coin Sense Harness to the installed spade taps.
Red connects to Red.
Blue connects to White/Blue.
White connects to White.
I-S0047
Part #: C-6361
Desc 1: Coin Sense Harness
Desc 2: Male taps, Rq. Female
Qty: 1
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5260
Desc 1: Wire Tap Bridge
Desc 2: 18-16 AWG
Qty: 2
Disconnect the Coin Drop from the Machine Control Assembly.
This harness must remain disconnected for FasCard to function properly. Reconnecting this harness after installation will damage the FasCard reader. Technical Support recommends taping off these connections.
Bridge the solid Red and solid Blue wires coming from the coin eye sensor using the C-5260 Wire Tap Bridge.
Bridge the Blue/Silver and solid Purple wires going to the machine control assembly using the C-5260 Wire Tap Bridge.
Tap the Red, White, and White/Blue wires with the C-5101 Spade Taps provided.
Connect the C-6361 Coin Sense Harness to the installed spade taps.
Red connects to Red.
Blue connects to White/Blue.
White connects to White.
Connect Machine Interface Harness
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Gen1 | SingleVend (MLV+) / 24ms | *NOT SUPPORTED* |