Overview
Equipment Details
Type: Tumble Dryer (Stack)
Manufacturer: ADC
Make: ADC
Model Length: Not Set
Associated Models
AD235
ADG235
ADG235D
Installation
Install Mounting Hardware
I-M0010
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0104
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0156
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Part #: C-6701
Desc 1: Adapter Plate
Desc 2: F1 to F2
Qty: 1
Part #: C-6601
Desc 1: Spacer
Desc 2: F2 Dexter Vault Filler Plate
Qty: 1
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-5436
Desc 1: Screw
Desc 2: 10-32 x 1" - Pan
Qty: 2
Place the C-5414 Mounting Bracket on top of the C-6601 Spacer Plate.
Place both Mounting Bracket and Spacer Plate over the mounting hole previously used by the coin drop.
Place the C-6701 Adapter Plate on the opposite side of the machine panel and secure in place using the C-5416 Screws.
Place the C-5710 Rubber Grommet into the circular opening of the C-5414 Mounting Bracket.
Connect Power
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0012
Part #: C-5343
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 5
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5343 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0056
Part #: C-5344
Desc 1: Machine Start Harness
Desc 2: ADC Phase 5
Qty: 1
Connect the C-5344 Machine Start Harness to the Coin 1 connection on the Machine Control Assembly.
Optional: Stack Add-on Installation
I-X0006
Part #: C-5344
Desc 1: Machine Start Harness
Desc 2: ADC Phase 5
Qty: 1
Part #: C-6348
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 5
Qty: 1
Part #: C-6400
Desc 1: Stack Add On Board - SLV
Desc 2: Pulse / SingleVend
Qty: 1
Run C-5344 Machine Start Harness and C-6348 Coin Sense Harness to the second Machine Control Assembly.
Connect C-5344 Machine Start Harness to the Coin 1 connection and the C-6348 Coin Sense Harness to the coin drop for the second Machine Control Assembly.
Connect the C-6400 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Port 2 on the reader.
Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to the Stack Add-on Board.
Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.
Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.
Connect and Mount Reader
F1 Reader
Feed remaining harness ends through the mounting hole as described in F1: FasCard Reader Mounting Guide.
Connect the free end of the C-5344 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the C-5343 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1: FasCard Reader Mounting Guide.
F2, F3, Flex, FlexRF
Feed remaining harness ends through the mounting hole as described in the F2/F3: FasCard Reader Mounting Guide.
Connect the free end of the C-5344 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the C-6348 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-5500 Power Harness to port 1.
Secure the FasCard reader to base as described in the FasCard Mounting Guide.
Machine Configuration
TODO
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Phase 5 | SingleVend (Relay) / 60ms | *NOT SUPPORTED* |