Overview
Equipment Details
Type: Washer
Manufacturer: Maytag
Make: Maytag
Model Length: 8 to 10
Associated Models
MAT20PDA00
MAT20PDAWW
MAT20PDAWW1
MAT20PRAWW
MAT20PRAWW1
MAT20PRAYW
MAT23PDAWW
MAT23PDAWW0
MAT23PRAWW
Installation
Install Mounting Hardware
I-M0009
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-0301
Desc 1: Topload Mounting Bolt
Desc 2:
Qty: 1
Part #: C-0911
Desc 1: Metercase Bracket
Desc 2: Whirlpool - White
Qty: 1
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Remove coin box and coin slide.
Install C-5771 Metercase Bracket into the front opening of the metercase and secure using C-0303 Topload Mounting Bolt from the inside.
After running the Cat5e cables and start harness through the front opening of the metercase bracket and connecting them to the LaundryCard reader, use the (2) C-0141 8-32 x 1-1/2" Socket Screws to secure the reader.
Apply the C-0015 Label to the front of the LaundryCard reader around the card slot.
Connect Power
I-P0026
Part #: C-1098
Desc 1: 3M Dual Lock 1" wide
Desc 2: Use 4" strips for C-5602
Qty: 1
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Locate the 120v power lines in the machine. These wires are usually black and white and are located just inside the back of the panel. Use a voltage tester to confirm the correct wiring.
Apply the C-5101 Spade Taps to both the black and white power wires and clamping them down with pliers.
Plug the brown wire of the C-5336 Power Adapter Harness to the white/neutral wire tap and the blue wire to the black/L1 wire tap.
Locate a green chassis ground screw and loosen to insert the green wire from the C-5336 Power Adapter Harness and retighten.
Connect the 3-pin connector from the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.
Apply the C-1098 Velcro to the C-5602R1 Power Converter and secure inside the machine's panel.
Connect the 4-pin connector from the C-5500 Power Extension Harness to the C-5602R1 Power Converter.
Route the 3-pin connector from the C-5500 Power Extension Harness through the open card slot on the machine control panel.
Connect Coin Sense Harness
I-S0020
Part #: C-5362
Desc 1: Coin Sense Harness
Desc 2: MLG
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5362 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0048
Part #: C-6362
Desc 1: Coin Sense Harness
Desc 2: MLG
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6362 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0004
Part #: C-5364
Desc 1: Machine Start Harness
Desc 2: Maytag MFR
Qty: 1
Locate the AA3 serial connection on the machine control board and plug in the C-5364 Machine Start Harness.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
MayTag AA3/Debit Connection Payment Pulse
Enter Service Mode by activating the service switch.
Locate Coin/Debit Option (J.) and set to Cd.
Enhanced Debit (Gen 2)
Enhanced Debit is self-selected when a Generation 2 card reader is installed in the dryer. The Ed option cannot be manually selected or deselected.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Gen2 | SingleVend (MLV+) / 24ms | Maytag Gen2 M17 Top-Load Washer |