Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Front Load Washer
Manufacturer: Maytag
Make: Maytag
Model Length: 10

Associated Models


MAH22PDAWW
MAH22PDBWW

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0008

Part #: C-0301

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-6911

Desc 1: F2 Metercase Bracket

Desc 2: Whirlpool - White

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin mechanism.

  2. Run reader harnesses through the metercase and out the opening where the coin mechanism was mounted.

  3. Attach the C-5414 Reader Bracket to the C-6911 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  4. Insert the reader harnesses through the hole in the C-6911 Metercase Bracket and then insert the bracket into the metercase opening.

  5. Secure the C-6911 Metercase Bracket to the metercase using the C-0301 Mounting Bolt.

Connect Power

Connect Machine Interface Harness

 I-T0089

Part #: C-5364

Desc 1: Machine Start Harness

Desc 2: Maytag MFR

   Qty: 1

Part #: C-0128-MBJ

Desc 1: Jumper Plug

Desc 2: Maytag Coin Vault

   Qty: 1

  1. Connect the C-5364 Machine Start Harness to the AA3 connection on the machine control assembly.

  2. Connect the C-0128-MBJ Jumper Plug into the harness connected to the Vault Switch.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

MayTag AA3/Debit Connection Payment Pulse

  1. Enter Service Mode by activating the service switch.

  2. Locate Coin/Debit Option (J.) and set to Cd.

  • No labels