You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 5
Next »
Overview
Equipment Details
Type: Tumble Dryer (Stack)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15
NetMaster Controls use in K and S Models through serial numbers (K) 1101018349 and (S) 0904004427.
Associated Models
CTT30N3VB2G2W02
CTT45NBCG2G2Q01
HTT30EKC1111N11
HTT30LBCB2G1L03
HTT30LBCB2G1Q03
HTT30LBCB2G1W03
HTT30LBCB2G2Q01
HTT30LBCB2G2W00
HTT30LBCB2G2W01
HTT30LKCB2G2W01
HTT30NBC8202N02
HTT30NBC82S1N01
HTT30NBCB202N02
HTT30NBCB202W01
HTT30NBCB251N01
HTT30NBCB262N02
HTT30NBCB2B2N01
HTT30NBCB2G1N01
HTT30NBCB2G1Q01
HTT30NBCB2G1W01
HTT30NBCB2G2N00
HTT30NBCB2G2N01
HTT30NBCB2G2N02
HTT30NBCB2G2N0X
HTT30NBCB2G2N19
HTT30NBCB2G2NO2
HTT30NBCB2G2NOX
HTT30NBCB2G2Q01
HTT30NBCB2G2W00
HTT30NBCB2G2W01
HTT30NBCB2G2W0X
HTT30NBCB2S1N00
HTT30NBCB2S1N01
HTT30NBCB2S1Q01
HTT30NBCB2S2N00
HTT30NBCB2S2N01
HTT30NBCBZ51N01
HTT30NBCD2G2W01
HTT30NBCF6G2N03
HTT30NBCG2S2N02
HTT30NBXB2G1W01
HTT30NBYB252N01
HTT30NBYB2G2N00
HTT30NBYB2G2N01
HTT30NBYB2G2N02
HTT30NBYB2G2N03
HTT30NBYB2G2N04
HTT30NBYB2G2W02
HTT30NBYB2S1W01
HTT30NBYB2S2N00
HTT30NBYB2S2N01
HTT30NBYB2S2N0X
HTT30NBYB2S2W02
HTT30NBYC2G2W02
HTT30NECB2G1N01
HTT30NECB2G1W01
HTT30NECB2S1L01
HTT30NECB2S1W01
HTT30NKCB2B2N08
HTT30NKCB2G2N01
HTT30NKCB2G2N02
HTT30NKCB2G2N06
HTT30NKCB2G2N08
HTT30NKCB2G2N10
HTT30NKCB2G2N11
HTT30NKCB2G2W01
HTT30NKCB2S2N02
HTT30NKCB2S2N03
HTT30NKYB2G2N03
HTT30NLCB2G2N02
HTT30NLCB2S2N02
HTT45LBCG2G2N02
HTT45LBCG2G2Q01
HTT45LBCG2G2W00
HTT45LBCG2G2W01
HTT45LKCG2G2W01
HTT45N3VG2G2W02
HTT45NBCB2B2N01
HTT45NBCB2G1N01
HTT45NBCB2G2N00
HTT45NBCB2G2N02
HTT45NBCB2G2N19
HTT45NBCB2G2W01
HTT45NBCB2G2W02
HTT45NBCB2S2N01
HTT45NBCF6G2N02
HTT45NBCG252N02
HTT45NBCG2G2N00
HTT45NBCG2G2N01
HTT45NBCG2G2N02
HTT45NBCG2G2N19
HTT45NBCG2G2Q01
HTT45NBCG2G2W00
HTT45NBCG2G2W01
HTT45NBCG2G2W03
HTT45NBCG2G2W13
HTT45NBCG2S0N01
HTT45NBCG2S2N00
HTT45NBCG2S2N02
HTT45NBCQ2G2W01
HTT45NBCX2G2W01
HTT45NBG62G2N01
HTT45NBXG2G2N01
HTT45NBYB2G2N00
HTT45NBYB2G2N01
HTT45NBYB2G2N02
HTT45NBYG232N02
HTT45NBYG252W01
HTT45NBYG2F2N02
HTT45NBYG2G2N01
HTT45NBYG2G2N02
HTT45NBYG2G2N03
HTT45NBYG2G2N0X
HTT45NBYG2G2W01
HTT45NBYG2S2N01
HTT45NBYG2S2N02
HTT45NBYG2S2W01
HTT45NECB2G1W01
HTT45NECG2G2W01
HTT45NKCB2G2N06
HTT45NKCG2G0N02
HTT45NKCG2G2N01
HTT45NKCG2G2N03
HTT45NKCG2G2N07
HTT45NKCG2G2N08
HTT45NKCG2G2N09
HTT45NKCG2G2N10
HTT45NKCG2G2NO1
HTT45NKCG2G2W01
HTT45NKCG2S2N02
HTT45NKYB2G2N02
HTT45NKYG2G2N02
HTT45NKYG2G2N03
HTT45NKYG2G2N05
HTT45NKYG2S2N01
HTT45RKCG2S2N01
ITT30N3VB2G1W01
ITT30N3VB2G2W01
ITT30N3VB2G2W11
ITT30N3XB2G2N02
ITT30N3XG2G2N01
ITT30NBCB2G2W01
ITT45N3VE2G2N08
ITT45N3VG2G2N01
ITT45N3VG2G2N08
ITT45N3VG2G2NO1
ITT45N3VG2G2W02
ITT45N3XG2G2N01
ITT45NBCG2G2N01
ITT45NBCG2G2NO1
ITT45NBG62G2N01
ITT45NBGG2G2N01
KTT30LBCB2H2N00
KTT30LBCB2H2N02
KTT30MBYB2H2N01
KTT30NBCB1H2N00
KTT30NBCB1H2N01
KTT30NBCB282N01
KTT30NBCB2G1N01
KTT30NBCB2H2N00
KTT30NBCB2H2N01
KTT30NBCB2H2W00
KTT30NBCB2H2W01
KTT30NBCB2H2W03
KTT30NBCB2S2N00
KTT30NBCB2S2N01
KTT30NBCG2H2N00
KTT30NBCG2H2N01
KTT30NBTB2H2N01
KTT30NBYB2G2N01
KTT30NBYB2H2N00
KTT30NBYB2H2N01
KTT30NBYB2H2W01
KTT30NBYG2H2N01
KTT30NNCB2H2N01
KTT30NNCB2H2W02
KTT30NNCB2H2W04
KTT30NNJB2H2N01
KTT30NNYB2S2W01
KTT45BNYG2H2N01
KTT45LBCG2H2N00
KTT45LBCG2H2N01
KTT45LNCG2H2N01
KTT45NBCB2H2N01
KTT45NBCG2A2N01
KTT45NBCG2G2W01
KTT45NBCG2H2N00
KTT45NBCG2H2N01
KTT45NBCG2H2W00
KTT45NBCG2H2W01
KTT45NBCG2S2N00
KTT45NBCG2S2N01
KTT45NBCG2S2W01
KTT45NBCV2H2N01
KTT45NBYB2H2N01
KTT45NBYB2H2W01
KTT45NBYG2H2N00
KTT45NBYG2H2N01
KTT45NBYG2H2NO1
KTT45NBYG2H2W00
KTT45NBYG2H2W01
KTT45NNCG2H2N01
KTT45NNCG2S2N02
KTT45NNYG2H2N01
PTT30NBCB2G2N07
PTT45NBCG2G2N01
PTT45NBCG2G2N02
STT30LBCB2G2W01
STT30LBYB2G2W01
STT30LBYF6G2W01
STT30LLCB2G2W01
STT30LNCB2G1Q01
STT30LWCB2G2N01
STT30MBYB2G2N01
STT30NBCB262N02
STT30NBCB2B1N01
STT30NBCB2G1N01
STT30NBCB2G1Q01
STT30NBCB2G1W01
STT30NBCB2G2N01
STT30NBCB2G2N02
STT30NBCB2G2N09
STT30NBCB2G2NO2
STT30NBCB2G2Q01
STT30NBCB2G2W01
STT30NBCB2G2W02
STT30NBCB2G2WO1
STT30NBCB2S1N01
STT30NBCBIG1W04
STT30NBCBZG2W01
STT30NBCD2G1N01
STT30NBCD2G2NO2
STT30NBCD2G2W01
STT30NBCEQG1N01
STT30NBCF6G2W02
STT30NBCG2G2W01
STT30NBCN2G2N02
STT30NBCN2G2W01
STT30NBXB261Q02
STT30NBXB2D1N02
STT30NBXB2G1N02
STT30NBXB2G1Q02
STT30NBYB2G1N01
STT30NBYB2G1Q01
STT30NBYB2G2N01
STT30NBYB2G2N02
STT30NBYB2G2NO1
STT30NBYB2G2W00
STT30NBYB2G2W02
STT30NBYB2S2N01
STT30NBYF6G1N01
STT30NBYF6G2N01
STT30NECB2G1N01
STT30NECB2G1W00
STT30NECB2G1W01
STT30NLCB2C2N02
STT30NLCB2G0W01
STT30NLCB2G2N02
STT30NLCB2G2W01
STT30NLCB2S2N01
STT30NLCB2S2N02
STT30NLCB2S2NO2
STT30NLCD2G2N02
STT30NLCD2G2NO2
STT30NLCG2G2N02
STT30NLXB2G2W01
STT30NLXV2G2W01
STT30NLYB2G2N02
STT30NLYB2S2N01
STT30NLYB2S2N02
STT30NLYF6G2W01
STT30NNCB2G1N04
STT30NNCB2G1Q04
STT30NNCB2G1W04
STT30NNCB2G2N02
STT30NNRB2G1Q02
STT30NWCB2G0N03
STT30NWCB2G0W03
STT30NWCB2G1N00
STT30NWCB2G1N01
STT30NWCB2G2N02
STT30NWCB2G2N04
STT30NWCB2G2Q01
STT30NWCB2G2Q02
STT30NWCB2G2W05
STT30NWCV2G2N04
STT30NWYB2G2N02
STT30NWYB2G2N03
STT30NZCB2G2N03
STT30NZRB2G1W01
STT45LBYB2G2W01
STT45LBYG2G2W01
STT45LWCB2G2N01
STT45LWCG2G2N01
STT45NBCB2B2W01
STT45NBCB2G1W01
STT45NBCB2G2N00
STT45NBCB2G2N03
STT45NBCB2G2W01
STT45NBCG262N03
STT45NBCG2G2N01
STT45NBCG2G2N02
STT45NBCG2G2N03
STT45NBCG2G2Q01
STT45NBCG2G2W01
STT45NBCG2G2W05
STT45NBCG2S2N01
STT45NBCGQG2N03
STT45NBYB2G2N00
STT45NBYB2G2W01
STT45NBYB2G2W02
STT45NBYE2G2N02
STT45NBYG2G2N01
STT45NBYG2G2N02
STT45NBYG2G2Q01
STT45NBYG2G2W01
STT45NBYG2S2N01
STT45NLCB2G0W01
STT45NLCB2S2N01
STT45NLCG2G0W01
STT45NLCG2G2N00
STT45NLCG2G2N02
STT45NLCG2G2N03
STT45NLCG2G2Q02
STT45NLCG2G2W00
STT45NLCG2G2W01
STT45NLCG2G2WO1
STT45NLCG2S2N01
STT45NLCG2S2NO1
STT45NLCG2S2NXX
STT45NLCG2S2W01
STT45NLXG2G2N01
STT45NLYG2G2N01
STT45NLYG2S2N01
STT45NNCG2G1N02
STT45NNCG2G2W01
STT45NNCGCG1N02
STT45NWCB2G0N03
STT45NWCB2G0W04
STT45NWCG102N02
STT45NWCG222N01
STT45NWCG2G0N03
STT45NWCG2G1NO4
STT45NWCG2G2N02
STT45NWCG2G2N04
STT45NWCG2G2NO4
STT45NWCG2G2W01
STT45NWCG2G2W05
STT45NWTG2G2N02
STT45NWYF6G2N01
STT45NWYG2G0N02
STT45NWYG2G2N02
STT45NWYG2G2N03
STT45WBCG2G2N03
Installation
Install Mounting Hardware
I-M0104
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0113
Part #: C-0144
Desc 1: Screw
Desc 2: 8-32 x 2" - Flat
Qty: 2
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Part #: C-6936
Desc 1: F2, Sm Vault Mount Bracket
Desc 2:
Qty: 1
Part #: C-5035
Desc 1: Label
Desc 2: 3-7/8" x 3-1/4"
Qty: 1
Remove Coin Box.
Disconnect harness connection from the Vault Switch. Connect both ends to the C-5365 Bypass Harness.
Spread the C-6936 Vault Mount Bracket wings to lock it into place once installed.
Insert the C-6936 Vault Mount Bracket into the Coin Vault.
Use the C-0144 screws, attach the C-5414 F2 Mounting Bracket to the C-6936 Vault Mount Bracket.
I-M0109
Part #: C-1060
Desc 1: Screw - Build: TK
Desc 2: 8-32 x 3/8" - Zinc
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-6970R1
Desc 1: F2, Bracket (revised)
Desc 2: Alliance Card Ready
Qty: 1
Install the C-6970R1 Alliance Mounting Bracket into the opening on the control panel for mounting card readers and coin drops.
Attach the C-5414 F2 Mounting Bracket to the C-6970 Alliance Mounting Bracket and secure using the C-1060 Screws.
Connect Power
I-P0028
Part #: C-5500-115
Desc 1: Power Extension Harness
Desc 2: 115"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Tap power as described in FasCard Reader Install - Universal Concepts using the C-5101 Spade Taps provided.
Connect the opposite end of the C-5210 Power Adapter Harness to the C-5602 Power Converter.
Connect the C-5500-115 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0027
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: F2
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0049
Part #: C-5300-NC
Desc 1: Machine Start Harness
Desc 2: Aliiance - Normally Closed
Qty: 1
Connect the C-5300-NC Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.
I-T0012
Part #: C-0110-TOP
Desc 1: Machine Start Harness
Desc 2: 36" - Alliance Pre-ACA
Qty: 1
Part #: C-0110-CP
Desc 1: Jumper Plug
Desc 2: Enables card mode on pre-ACA
Qty: 1
Connect the C-0110-TOP Machine Start Harness to the H3 connector on the Machine Control Assembly.
I-X0003
Part #: C-5300-NC-144
Desc 1: Machine Start Harness
Desc 2: 144" Alliance
Qty: 1
Part #: C-6250-144
Desc 1: Coin Sense Harness
Desc 2: 144" length
Qty: 1
Part #: C-6400
Desc 1: Stack Add On Board - SLV
Desc 2: Pulse / SingleVend
Qty: 1
Run C-5300-NC-144 Machine Start Harness and C-6250-144 Coin Sense Harness to the second Machine Control Assembly.
Connect C-5300-NC-144 Machine Start Harness to the Coin 1 connection and the C-6250-144 Coin Sense Harness to the Coin Drop on the second Machine Control Assembly.
Connect the C-6400 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Port 2 on the FasCard Reader.
Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Stack Add-on Board.
Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.
Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.
Instructions do not exist for Kit I-X0004
Instructions do not exist for Kit I-X0009
I-X0025
Part #: C-6401
Desc 1: Stack Add On Board - MLV
Desc 2: Serial / MultiVend
Qty: 1
Part #: C-0110-TOP-144
Desc 1: Machine Start Harness
Desc 2: 144" - Alliance Pre-ACA
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Part #: C-0110-CP
Desc 1: Jumper Plug
Desc 2: Enables card mode on pre-ACA
Qty: 1
Run C-0110-TOP-144 Machine Start Harness to the second Machine Control Assembly.
Connect C-0110-TOP-144 Machine Start Harness to the H3 connection on the second Machine Control Assembly.
Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.
Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.
I-X0026
Part #: C-0110-TOP-144
Desc 1: Machine Start Harness
Desc 2: 144" - Alliance Pre-ACA
Qty: 1
Part #: C-6250-144
Desc 1: Coin Sense Harness
Desc 2: 144" length
Qty: 1
Part #: C-0110-CP
Desc 1: Jumper Plug
Desc 2: Enables card mode on pre-ACA
Qty: 1
Part #: C-6411
Desc 1: F3, MLV Stack Add On Dongle
Desc 2: Serial / MultiVend
Qty: 1
The following steps assume the start and coin sense harnesses are already connected to the upper pocket control.
Locate area to mount C-6411 Serial Stack Add-On Board.
Must be close enough to reader mounting location to connect the harness to.
Must be on a surface that does not received direct exposure from any heating elements (If applicable.)
Clean mounting location to remove any dust and residue if needed.
Remove the sticker from the back of the C-6411 Serial Stack Add-On Board to expose the adhesive and apply to the mounting location.
Connect the white, 7-pin connector from the C-0110-TOP to the H3 connection on the lower pocket's Machine Control Assembly.
Connect the the clear, 3-pin circuit board end from the C-6250-144 Coin Sense Harness to the lower pocket's Coin Drop.
I-X0027
Part #: C-0110-TOP-144
Desc 1: Machine Start Harness
Desc 2: 144" - Alliance Pre-ACA
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Part #: C-0110-CP
Desc 1: Jumper Plug
Desc 2: Enables card mode on pre-ACA
Qty: 1
Part #: C-6411
Desc 1: F3, MLV Stack Add On Dongle
Desc 2: Serial / MultiVend
Qty: 1
The following steps assume the start and coin sense harnesses are already connected to the upper pocket control.
Locate area to mount C-6411 Serial Stack Add-On Board.
Must be close enough to reader mounting location to connect the harness to.
Must be on a surface that does not received direct exposure from any heating elements (If applicable.)
Clean mounting location to remove any dust and residue if needed.
Remove the sticker from the back of the C-6411 Serial Stack Add-On Board to expose the adhesive and apply to the mounting location.
Connect the white, 7-pin connector from the C-0110-TOP to the H3 connection on the lower pocket's Machine Control Assembly.
Apply the C-5033 Label over the coin drop opening for the lower pocket.
I-X0048
Part #: C-6401
Desc 1: Stack Add On Board - MLV
Desc 2: Serial / MultiVend
Qty: 1
Part #: C-0110-TOP-144
Desc 1: Machine Start Harness
Desc 2: 144" - Alliance Pre-ACA
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Part #: C-0110-CP
Desc 1: Jumper Plug
Desc 2: Enables card mode on pre-ACA
Qty: 1
Part #: C-0940
Desc 1: Vault Cover
Desc 2: 3-7/8" x 2-3/4"
Qty: 1
Run C-0110-TOP-144 Machine Start Harness to the lower pocket Machine Control Assembly.
Pulse Setup
Connect the C-0110-TOP-144 Machine Start Harness to the H5 connection on the Machine Control Assembly.
C-0110-CP Jumper Plug is not used, but can be retained in case of future serial communication usage usage.
Serial Setup
Connect the C-0110-TOP-144 Machine Start Harness to the H5 connection on the Machine Control Assembly.
Connect the C-0110-CP Jumper Plug to the H2 connection on the Machine Control Assembly.
Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the reader.
Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.
Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.
Bend the side tabs of the C-0940 Vault Bracket outward and install into the coin vault for the lower pocket. The tabs should snap into place securing the bracket.
Apply the C-5033 Label over the opening for the lower pocket’s coin drop.
I-X0050
Part #: C-0110-TOP-144
Desc 1: Machine Start Harness
Desc 2: 144" - Alliance Pre-ACA
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Part #: C-0110-CP
Desc 1: Jumper Plug
Desc 2: Enables card mode on pre-ACA
Qty: 1
Part #: C-6411
Desc 1: F3, MLV Stack Add On Dongle
Desc 2: Serial / MultiVend
Qty: 1
Part #: C-0940
Desc 1: Vault Cover
Desc 2: 3-7/8" x 2-3/4"
Qty: 1
The following steps assume the start harness for the upper pocket control is already connected.
Run C-0110-TOP-144 Machine Start Harness to the lower pocket Machine Control Assembly.
Pulse Setup
Connect the C-0110-TOP-144 Machine Start Harness to the H3 connection on the Machine Control Assembly.
C-0110-CP Jumper Plug is not used, but can be retained in case of future serial communication usage usage.
Serial Setup
Connect the C-0110-TOP-144 Machine Start Harness to the H3 connection on the Machine Control Assembly.
Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.
Locate area to mount C-6411 Serial Stack Add-On Dongle.
Must be close enough to reader mounting location to connect the harness to.
Must be on a surface that does not received direct exposure from any heating elements (If applicable.)
Clean mounting location to remove any dust and residue if needed.
Remove the sticker from the back of the C-6411 Serial Stack Add-On Dongle to expose the adhesive and apply to the mounting location.
Connect the C-6411 Stack Add-on Dongle to port 5 (Serial Connection Port) on the card reader.
Connect the C-0110-TOP Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Dongle.
Connect the C-0110-TOP-144 Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Dongle.
Bend the side tabs of the C-0940 Vault Bracket outward and install into the coin vault for the lower pocket. The tabs should snap into place securing the bracket.
Apply the C-5033 Label over the opening for the lower pocket’s coin drop.
Connect and Mount Reader
Feed remaining harness ends through the mounting holes.
(Standard Installations - No Stack Add-On Kit) Connect the free end of the Machine Start Harness:
If following steps for a serial, connect the C-0110-TOP Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
If following steps for a pulse, connect the C-5300-NC Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
(F2/F3 - Serial Stack Add-On Installations Only) Connect the black, 10-pin connector from the C-0110-TOP Machine Start Harness to the Unit 1 connection and the C-0110-TOP Machine Start Harness to the Unit 2 connection on the C-6401 or C-6411 Serial Stack Add-On Board.
(Coin and Card Installations Only) Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-5500-115 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F2 Reader Mounting Guide.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
*NO NAME* | *NOT SUPPORTED* | *NOT SUPPORTED* |
Dual Digital Timer (OPL) | *NOT SUPPORTED* | *NOT SUPPORTED* |
DX4 (OPL) | *NOT SUPPORTED* | *NOT SUPPORTED* |
DX4 (Vended) | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
EDC | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
Galaxy 600 (C3) | SingleVend (MLV+) / 80ms | Alliance Centurion Tumbler Dryer C3 - Galaxy 600 |
LED (OPL) | *NOT SUPPORTED* | *NOT SUPPORTED* |
MDC (OPL) | *NOT SUPPORTED* | *NOT SUPPORTED* |
MDC (Vended) | SingleVend (MLV+) / 80ms | Alliance MDC Tumbler Dryer |
Micro (OPL) | *NOT SUPPORTED* | *NOT SUPPORTED* |
NetMaster | SingleVend (MLV+) / 80ms | *NOT SUPPORTED* |
NetMaster | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
Quantum Gold (C4) | SingleVend (MLV+) / 80ms | Alliance Centurion Tumbler Dryer C4 - Quantum Gold |