Skip to end of banner
Go to start of banner

3105 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Maytag
Make: Maytag
Model Length: 8 to 10

Associated Models

MAT20PDA00
MAT20PDAWW
MAT20PDAWW1
MAT20PRAWW
MAT20PRAWW1
MAT20PRAYW
MAT23PDAWW
MAT23PDAWW0
MAT23PRAWW

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0010

Part #: C-5801

Desc 1: F1 Reader Mounting Kit

Desc 2: Front

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0085

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-0303

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-5027

Desc 1: Label

Desc 2: Credit Card Logo

   Qty: 1

Part #: C-5771

Desc 1: Metercase Bracket

Desc 2: Coin Drop Ready Machines

   Qty: 1

  1. Remove coin box and coin slide.

  2. Install C-5771 Metercase Bracket and secure using C-0303 Topload Mounting Bolt.

 I-M0135

Part #: C-5801

Desc 1: F1 Reader Mounting Kit

Desc 2: Front

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0009

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-0301

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-0911

Desc 1: Metercase Bracket

Desc 2: Whirlpool - White

   Qty: 1

Part #: C-0015

Desc 1: Label

Desc 2: Reader Cover Label

   Qty: 1

  1. Remove coin box and coin slide.

  2. Install C-5771 Metercase Bracket into the front opening of the metercase and secure using C-0303 Topload Mounting Bolt from the inside.

  3. After running the Cat5e cables and start harness through the front opening of the metercase bracket and connecting them to the LaundryCard reader, use the (2) C-0141 8-32 x 1-1/2" Socket Screws to secure the reader.

  4. Apply the C-0015 Label to the front of the LaundryCard reader around the card slot.

 I-M0044

Part #: C-0015

Desc 1: Label

Desc 2: Reader Cover Label

   Qty: 1

Part #: C-0144

Desc 1: Screw

Desc 2: 8-32 x 2" - Flat

   Qty: 2

Part #: C-0930

Desc 1: Mounting Bracket

Desc 2: Unimac/ADC

   Qty: 1

  1. Use the C-0930 Mounting Bracket to mark out the center opening for the card reader and the lower set of holes to the left and right of the central opening.

    1. Ensure the positing leaves enough space for the reader's bezel to sit flat against the machine's panel and for the reader to be inserted into the machine and allow for the CAT5 cables to be connected.

  2. Cut out the central opening and use a 9/64" Drill Bit to make a hole at each drill marks to the left and right of the central opening.

  3. Place the C-0930 Mounting Bracket on the inside of the machine's panel. Pass through and connect the CAT5 cables and machine start harness to the reader.

  4. Use the (2) C-0144 8-32 x 2" Flat Screw to attach the reader to the C-0930 Mounting Bracket.

  5. Apply C-0015 Label over the area around the card slot on the front of the LaundryCard reader.

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0122

Part #: C-0303

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-6911

Desc 1: F2 Metercase Bracket

Desc 2: Whirlpool - White

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin mechanism.

  2. Run reader harnesses through the metercase and out the opening where the coin mechanism was mounted.

  3. Attach the C-5414 Reader Bracket to the C-6911 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  4. Insert the reader harnesses through the hole in the C-6911 Metercase Bracket and then insert the bracket into the metercase opening.

  5. Secure the C-6911 Metercase Bracket to the metercase using the C-0301 Mounting Bolt.

 I-M0187

Part #: C-6980

Desc 1: Maytag Bk Splash Mount

Desc 2: F2

   Qty: 1

Part #: C-1042

Desc 1: Nut

Desc 2: 8-32 - Kep

   Qty: 1

Part #: C-1070-W

Desc 1: Washer - Build: XCH

Desc 2: 1/4" x 1" O.D.

   Qty: 1

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

  1. Remove the (4) Security T20 retaining screws from the front of the machine.

  2. Lift up and pull panel forward and lay on machine. NOTE: The front panel may come apart, as it is two parts. Take care not to damage the ribbon cable.

  3. Mount the C-6980 Mounting Bracket on the front of the panel so that the holes match on the right and the retaining screw on the back of the plate goes through the card slot.

  4. Place the C-1070-W Washer and C-1042 Keps Nut onto the retaining screw and tighten using 11/32 socket to secure the mounting bracket. The bracket should feel slightly loose until the panel is reattached to the machine.

Connect Power

 I-P0026

Part #: C-1098

Desc 1: 3M Dual Lock 1" wide

Desc 2: Use 4" strips for C-5602

   Qty: 1

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 2

Part #: C-5336

Desc 1: Power Adapter Harness

Desc 2: Dexter Stack

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Locate the 120v power lines in the machine. These wires are usually black and white and are located just inside the back of the panel. Use a voltage tester to confirm the correct wiring.

  2. Apply the C-5101 Spade Taps to both the black and white power wires and clamping them down with pliers.

  3. Plug the brown wire of the C-5336 Power Adapter Harness to the white/neutral wire tap and the blue wire to the black/L1 wire tap.

  4. Locate a green chassis ground screw and loosen to insert the green wire from the C-5336 Power Adapter Harness and retighten.

  5. Connect the 3-pin connector from the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.

  6. Apply the C-1098 Velcro to the C-5602R1 Power Converter and secure inside the machine's panel.

  7. Connect the 4-pin connector from the C-5500 Power Extension Harness to the C-5602R1 Power Converter.

  8. Route the 3-pin connector from the C-5500 Power Extension Harness through the open card slot on the machine control panel.

Connect Coin Sense Harness

 I-S0048

Part #: C-6362

Desc 1: Coin Sense Harness

Desc 2: MLG

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6362 Coin Sense Harness to the harness connected to the Coin Drop.

 I-S0020

Part #: C-5362

Desc 1: Coin Sense Harness

Desc 2: MLG

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-5362 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0004

Part #: C-5364

Desc 1: Machine Start Harness

Desc 2: Maytag MFR

   Qty: 1

Locate the AA3 serial connection on the machine control board and plug in the C-5364 Machine Start Harness.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

MayTag AA3/Debit Connection Payment Pulse

  1. Enter Service Mode by activating the service switch.

  2. Locate Coin/Debit Option (J.) and set to Cd.

Enhanced Debit (Gen 2)

Enhanced Debit is self-selected when a Generation 2 card reader is installed in the dryer. The Ed option cannot be manually selected or deselected.

  • No labels