This page is intended to guide the user through the proper reboot and shutdown procedures for the CCI-provided computer stored within each X-Changer cabinet. Each location may operate on a different version of LaundryCard, therefore a few screens may be different in the processes outlined below.


Determine the Primary system

It is imperative to know which X-Changer is labeled as the Primary. Failure to reboot the appropriately labeled X-Changer at the right time may result in data loss.

Warning

If both X-Changers are displayed as the database Primary or the database Backup, call CCI Technical Support immediately.

Method 1 – LaundryCard main page

Version 6.5 and higherVersion 9

LaundryCard software versions 6.5 and higher display Primary and Backup indicators in the upper left-hand corner of the screen when LaundryCard applications are running.

Older software versions require different methods to obtain Primary and Backup information.

LaundryCard software version V9 displays the Primary in the center of the home screen when using a Manager, Attendant, or Technician card.

Method 2 – Use the Store Status page to determine the Primary system

Insert a Manager, Attendant, or Technician card and navigate to the Store Status page.

Version 5 and 6Version 7 and 8Version 9

In V5 and V6, the Primary database will be in the 'Database' row. If CCI1 is listed here, that corresponds to X-Changer A. CCI2 corresponds to X-Changer B.

In V7 and V8, the Primary database is clearly labeled as such in the top row of the System Status section.In V9, the Primary database is found in the Store status screen under the Maintenance Menu.  The primary is listed under "System Status" as well as at the top of the screen.

LaundryCard Versions 5 and 6Image Modified

LaundryCard Version 7 and 8Image Modified

LaundryCard Version 9Image Modified

Reboot procedures

Multiexcerpt include macro
nameUIExpand
templateData[]
pageCCIDOC:_Macros
addpanelfalse

Ui expand
titleIf the system to be rebooted is Database Backup

Frequency of Maintenance: Monthly

  1. Insert a Manager's card (or a card with maintenance permissions) on the Backup X-Changer and access the Maintenance menu.
  2. Press the Restart System button.

  3. Choose the appropriate button to reboot the Backup X-Changer.

  4. Windows will prompt for the confirmation of reboot. Click OK to confirm.


Ui expand
titleIf the system to be rebooted is Database Primary

Frequency of Maintenance: Monthly

  1. Insert a Manager's card (or a card with maintenance permissions) on the Primary X-Changer and access the Maintenance menu.
  2. Press the System Error Messages button.

  3. Verify no database backup errors are present.



    1. If database backup errors are present, contact CCI Technical Support before proceeding.
  4. Press the Back button.
  5. Press the Restart System button.

  6. Choose Failover to Backup.

  7. KeepAGoin will display a popup indicating a database backup has been completed. Click OK to confirm.


  8. Windows will prompt for the confirmation of reboot. Click OK to confirm.

    1. If you do not receive this prompt, go back to the Restart System menu and reboot the desired X-Changer.

Shutdown procedures

Required hardware

  • USB keyboard
  • USB Mouse or touchscreen

Multiexcerpt include macro
nameUIExpand
templateData[]
pageCCIDOC:_Macros
addpanelfalse

Ui expand
titleIf system to be shutdown is Database Backup
  1. Connect the keyboard to an available USB port on the computer and press the Windows key located along the bottom row.

  2.  A Start menu will appear at the bottom left corner of the screen. Using the touch screen or a mouse, click Shut Down.


    1. In version 9 you will need to press the power button, located on the bottom left corner of the Start menu.

      Version 7Version 8

      Version 9

      Version 7

      Version 8

      Version 9


  3. A window appears which allows log off, restart, or shut down. Select the desired option then click OK.

    Version 7Version 8

    Version 9

    Version 7

    Version 8

    Version 9


  4. Wait for the computer to shut down. All lights on the front of the computer should turn off and the monitor will go blank.


Ui expand
titleIf system to be shutdown is Database Primary
  1. Insert a Manager's card (or a card with maintenance permissions) on the Primary X-Changer and access the Maintenance menu.
  2. Press the System Error Messages button.

  3. Verify no database backup errors are present.



    1. If database backup errors are present, contact CCI Technical Support before proceeding.
  4. Click the Back button.
  5. Click the Restart System button.

  6. Choose Failover to Backup.

  7. KeepAGoin will display a popup indicating a database backup has been completed. Click OK to confirm.

  8. Windows will prompt for the confirmation of reboot. Click Cancel.


    1. If this prompt does not populate, then proceed to step 10.

  9. Connect the keyboard to an available USB port on the computer and press the Windows key located along the bottom row.

               

  10.  A Start menu will appear at the bottom left corner of the screen. Using the touch screen or a mouse, click Shut Down.


    1. In version 9 you will need to press the power button, located on the bottom left corner of the Start menu.

      Version 7Version 8

      Version 9

      Version 7

      Version 8

      Version 9


  11. A window appears which allows log off, restart, or shut down. Select the desired option then click OK.

    V7V8V9

    Version 7

    Version 8

    Version 9


  12. Wait for the computer to shut down. All lights on the front of the computer should turn off and the monitor will go blank.