Place the C-6700-TEMPDrill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to for further instructions.
Cci readerinstall kit
KitID
863
KitDesc
Card Only
Remove existing coin box.
Remove Vault Switchand bridge the wires previously connected to the Vault Switchwith the C-5365Bypass Harness.
Bend the side tabs of theC-6602Vault Bracketoutward and install into the coin vault. The tabs should snap into place securing the bracket.
Arrange both the C-5414 Mounting Bracket and theC-0906Spacer so the smaller screw holes align. Secure both to the C-6601 Vault Mount so that the C-0906 Spacer is between the machine panel and the C-5414 Mounting Bracket.
Apply the C-5033 Label over the coin drop opening.
Connect Power
Cci readerinstall kit
KitID
663
Tap power as described in the document by connecting theC-5336Power Adapter Harnessto the power distribution panel inside the machine.
120vac: Connect the blue wire to L1 and the brown wire to N using theC-5101Spade Taps.
240vac: Connect the blue wire to L1 and the brown wire to L2 using theC-5101Spade Taps.
Secure the green wire beneath the ground screw.
Connect the opposite end of theC-5336Power Adapter Harnessto theC-5602R1Power Converter.
Connect theC-5500Power Extension Harness to the appropriate connector on theC-5602R1Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
Cci readerinstall kit
KitID
719
KitDesc
Coin Drop: Factory
Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.
Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.
Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.
Connect Machine Interface Harness
Cci readerinstall kit
KitID
984
KitDesc
Pulse
Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.
Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.
Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)
Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)
Connect and Mount Reader
Multiexcerpt include
SpaceWithExcerpt
CCIDOC
MultiExcerptName
F2 Reader
PageWithExcerpt
_Reader Ports
Item No.
Component
Notes
1
Power Connection Port
Utilizes the same power harnesses as the first generation FasCard reader.
2
Pulse Connection Port
Connection point for pulse machine start harnesses.
3
Coin 1 Connection Port
This is the connection point for the harness input associated with Coin 1.
4
Coin 2 Connection Port
This is the connection point for the harness input associated with Coin 2.
5
Serial Connection Port