Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Overview
Equipment Details
Type: Washer Extractor
Manufacturer: Alliance
Make: Huebsch
Model Length: 18
Associated Models
HYT020VX0HXUB0C0BA
HYT020VX0HXUB0C0FQ
HYT030VCAHXUB0C0BA
HYT030VX0HXUB0C0BA
HYT030VX0HXUB0C0FQ
HYT030VX0HXUB0X0BA
HYT040VCAHXUB0C0BA
HYT040VCAHXUB0E0BA
HYT040VX0HXUB0E0FQ
HYT055VCAHXUB0E0BA
HYT055VCAHXUB0X0BA
HYT055VX0HXUB0E0BA
HYT055VX0HXUB0E0FQ
HYT070VCAHXUB0C0BA
HYT070VCAHXUB0E0BA
HYT070VX0HXUB0E0FQ
SYT020VCAHXUB0C0BA
SYT020VX0HXUB0C0BA
SYT030VCAHXUB0C0FQ
SYT040VCAHXUB0E0BA
SYT040VX0HXUB0E0BA
SYT055VX0HXUB0E0BA
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Item No. | Component | Notes |
1 | Power Connection Port | Utilizes the same power harnesses as the first generation FasCard reader. |
2 | Pulse Connection Port | Connection point for pulse machine start harnesses. |
3 | Coin 1 Connection Port | This is the connection point for the harness input associated with Coin 1. |
4 | Coin 2 Connection Port | This is the connection point for the harness input associated with Coin 2. |
5 | Serial Connection Port | This is the connection point for serial machine start harnesses. |
- Feed remaining harness ends through the mounting hole as described in the Touchscreen Reader Mounting Guide (F2 & F3).
- Connect the free end of the C-5265 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the C-6360 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Harness to port 1.
- Secure the FasCard reader to base as described in the Touchscreen Reader Mounting Guide (F2 & F3).
Machine Configuration
Singlevend - Coin Pulse
- Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
- Machine Settings
- Liquid Soap Supply: Enabled
- Payment Settings:
- Enable Types: Disable all payment types
- Coin Options: Single
- Coin 1 Value: Intended Vend Price
- Coin 2 Value: Intended Vend Price
- Serial Payment System: Disabled
- Machine Settings
- On the FasCard Admin site, create a SingleVend equipment type with the following settings:
- Mode: Simple
- Pulse Length: 1000
- Pulse Interval: 250
- Pulse Type: Relay
- Sensor Input: Required Off
- Show Remaining Time: Disabled
- Cycle Time: 600 Seconds
- # Pulses: 1
CCI Software Configuration
Machine Control | Pulse | Serial |
---|---|---|
MC10 | SingleVend (Relay) / 1000ms | Alliance Quantum Touch Washer Extractor |
Additional Resources
- How to Program Address on a FasCard Reader
- FasCard Admin Site - Equipment Setup
- FasCard Admin Site - Machine Setup
- FasCard Admin Site - Pricing & Features Schedule
- F1 Reader Mounting Guide
- FasCard F2/F3 Reader Installation Guide - Front Mount
- FasCard Installation Videos
- FasCard Kit Installations - Machine Configurations & Related Documents