3638 Reader Install Guide

3638 Reader Install Guide

Machine Configuration

Singlevend - Coin Pulse

  1. Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)

    1. Machine Settings

      1. Liquid Soap Supply: Enabled

    2. Payment Settings:

      1. Enable Types: Disable all payment types

      2. Coin Options: Single

      3. Coin 1 Value: Intended Vend Price

      4. Coin 2 Value: Intended Vend Price

      5. Serial Payment System: Disabled

  2. On the FasCard Admin site, create a SingleVend equipment type with the following settings:

    1. Mode: Simple

    2. Pulse Length: 1000

    3. Pulse Interval: 250

    4. Pulse Type: Relay

    5. Sensor Input: Required Off

    6. Show Remaining Time: Disabled

    7. Cycle Time: 600 Seconds

    8. # Pulses: 1