Cci readerinstall kit
KitID616
KitDescCoin and Card
  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F1 Reader Mounting Guide for further instructions.

Cci readerinstall kit
KitID796
KitDescCard Only
  1. Remove existing coin box and coin drop.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.

  3. Bend the side tabs of the C-0936 Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Attach the C-0133 Standoffs to the Bracket.

  5. Attach reader to C-0936 Vault Mount Bracket using C-0144 Screws.

  6. Apply C-5033 Label over the coin drop opening.

    1. Optional: Apply C-5027 Label on or near the reader for any accepted credit card issuers.

Cci readerinstall kit
KitID584
KitDescCoin and Card
  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to Touchscreen Reader Mounting Guide (F2 & F3) for further instructions.

Cci readerinstall kit
KitID863
KitDescCard Only
  1. Remove existing coin box.

  2. Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.

  3. Bend the side tabs of the C-6602 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Arrange both the C-5414 Mounting Bracket and the C-0906 Spacer so the smaller screw holes align. Secure both to the C-6601 Vault Mount so that the C-0906 Spacer is between the machine panel and the C-5414 Mounting Bracket.

  5. Apply the C-5033 Label over the coin drop opening.

Connect Power

Cci readerinstall kit
KitID663
  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5336 Power Adapter Harness to the power distribution panel inside the machine.

    1. 120vac: Connect the blue wire to L1 and the brown wire to N using the C-5101 Spade Taps.

    2. 240vac: Connect the blue wire to L1 and the brown wire to L2 using the C-5101 Spade Taps.

    3. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Cci readerinstall kit
KitID691
KitDescCoin Drop: Factory
  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-5360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

Cci readerinstall kit
KitID719
KitDescCoin Drop: Factory
  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

Connect Machine Interface Harness

Cci readerinstall kit
KitID984
KitDescPulse
  1. Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.

  2. Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.

  3. Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)

  4. Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)

Connect and Mount Reader

...

Include Page

...

SpaceWithExcerptCCIDOC
MultiExcerptNameF2 Reader
PageWithExcerpt_Reader Ports

...

_Reader Connections
_Reader Connections

Machine Configuration

Singlevend - Coin Pulse

  1. Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)

    1. Machine Settings

      1. Liquid Soap Supply: Enabled

    2. Payment Settings:

      1. Enable Types: Disable all payment types

      2. Coin Options: Single

      3. Coin 1 Value: Intended Vend Price

      4. Coin 2 Value: Intended Vend Price

      5. Serial Payment System: Disabled

  2. On the FasCard Admin site, create a SingleVend equipment type with the following settings:

    1. Mode: Simple

    2. Pulse Length: 1000

    3. Pulse Interval: 250

    4. Pulse Type: Relay

    5. Sensor Input: Required Off

    6. Show Remaining Time: Disabled

    7. Cycle Time: 600 Seconds

    8. # Pulses: 1

Multiexcerpt fast include inline macro
nameMidas
templateDataeJyLjgUAARUAuQ==
page_Machine Configuration
addpanelfalse

Cci readerinstall footer