Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
PanelborderColor#416EB6titleColor#E6E6E6titleBGColor#416EB6title

Overview

This page is intended to guide the installer through the replacement of the standard components considered to be field replaceable in an F2 FasCard Reader.

Multiexcerpt include
SpaceWithExcerptCCIDOC
MultiExcerptNameWarning
PageWithExcerptCCIDOC:_General

Required parts & tools 

Bw part list
Partsc-5431,c-5432,C-5415
ShowImagetrue
ShowDesc1true

Tools and Supplies (Not Included)

Description

SourceImage
  • 8-32" Torx Security Driver (T15)

Amazon

Image Removed

  • No.2 Phillips Screwdriver


  • (or equivalent)

 Amazon

Image Removed

Step-by-step guides

Expand
titleTouchscreen Assembly replacement

Required part(s)

Bw part list
Partsc-5415
ShowImagetrue
ShowDesc1true

Step 1 - Remove F2 FasCard Reader from mount

  1. Locate and remove the C-5416 security screws underneath the FasCard reader.

Fig. 1aImage Removed
  1. Fig. 1aImage Added
  2. Gently pull the bottom of the reader forward until it clears the bottom of the C-5414 mounting bracket. 

Fig. 1bImage Removed
  1. Fig. 1bImage Added
  2. Lift the top of the reader clear of the C-5414 mounting bracket. 

  3. Disconnect all harnesses connected to the reader. 

Fig. 1cImage Removed
  1. Fig. 1cImage Added

Step 2 - Disconnecting the display housing from the main housing

  1. Disconnect the MagStripe Reader (MSR) from the control board. 

Fig. 2aImage Removed
  1. Fig. 2aImage Added
  2. Identify and remove the four (4) Philips screws. 

Fig. 2bImage Removed
  1. Fig. 2bImage Added
  2. Gently lift the display housing (with the control board attached) from the main reader housing. 

Fig. 2cImage Removed
  1. Fig. 2cImage Added

Step 3 - Disconnecting the display housing from the Control Board

  1. Disconnect the display cable by pulling the black tab outwards, towards the cable. 

Fig. 3aImage Removed
  1. Fig. 3aImage Added
  2. Disconnect the interface cable by lifting the "T" portion (from the sides). 

Fig. 3bImage Removed
  1. Fig. 3bImage Added
  2. The display housing is connected to the control board with a small plastic clip. 

  3. Using gentle pressure, lift the bottom edge of the circuit board free of the corner pegs.

    1. CCI Technical Support recommends setting the control board on a static-resistant surface.

Fig. 3cImage Removed
    1. Fig. 3cImage Added

Step 4 - Mounting the Control Board on the replacement Display Housing

  1. Place the mounting hole shown in Step 3, 4.a. above, over the mounting clip. 

  2. Gently maneuver the Control Board into a locked position with the four corner posts. 

  3. Connect the display cable to the slot. 

    1. Hold the cable in place and slide the black tab into the connector to lock it into place.

  4. Connect the interface cable pushing down gently until it locks into place. 

Step 5 - Connect the Display Housing to the Main Housing

  1. Slide the Main Housing onto the Display Housing and secure them together with the screws from Steps 2, 2..

Fig. 5aImage Removed
  1. Fig. 5aImage Added
  2. Reconnect the MSR cable. 

Fig. 5bImage Removed
  1. Fig. 5bImage Added
  2. Remount the reader onto the machine. 

    1. Refer to FasCard F2/F3 Reader Installation Guide - High-Front & Top-Mount, or;

    2. Refer to FasCard F2/F3 Reader Installation Guide - Front Mount.

Expand
titleMagnetic Stripe Reader Replacement

Required part(s)

Bw part list
Partsc-5431,c-5432
ShowImagetrue
ShowDesc1true

 

Step 1 - Removing the F2 FasCard reader from the mount

  1. Locate and remove the C-5416 security screws underneath the FasCard reader. 

Fig. 1aImage Removed

  1. Fig. 1aImage Added




  2. Gently pull the bottom of the reader forward until it clears the bottom of the C-5414 mounting bracket. 

Fig. 1bImage Removed

  1. Fig. 1bImage Added



  2. Lift the top of the reader clear of the C-5414 mounting bracket. 

  3. Disconnect all harnesses connected to the reader. 

Fig. 1cImage Removed

  1. Fig. 1cImage Added



Step 2 - Disconnecting the display housing from the main housing

  1. Disconnect the MagStripe Reader (MSR) from the control board. 

Fig. 2aImage Removed

  1. Fig. 2aImage Added




  2. Identify and remove the four (4) Philips screws. 

Fig. 2bImage Removed

  1. Fig. 2bImage Added



  2. Gently lift the display housing (with the control board attached) from the main reader housing. 

Fig. 2cImage Removed

  1. Fig. 2cImage Added

Step 3 - Disconnected the Magnetic Stripe Reader (MSR) from the Main Housing

  1. Locate the C-5431 or C-5432 MSR assembly in the Main Housing. 

  2. With gentle pressure, lift the leading edge (opposite of the clips) clear of the mounting groove. 

Fig. 3bImage Removed

  1. Fig. 3bImage Added



  2. The MSR may now be lifted up and away from the clips that were highlighted above. 

Fig. 3cImage Removed

  1. Fig. 3cImage Added

Step 4 - Connecting the replacement MSR to the Main Housing

  1. Reverse Step 3, 2. to connect the C-5431 or C-5432 replacement MSR assembly to the main housing. 

  2. The plastic housing has some flex to it and will lock together with gentle pressure if the reader housing is properly aligned. 

Step 5 - Connect the Display Housing to the Main Housing

  1. Slide the Main Housing onto the Display Housing and secure them together with the screws from Step 2, 2.. 

Fig. 5aImage Removed

  1. Fig. 5aImage Added



  2. Reconnect the MSR cable. 

Fig. 5bImage Removed