Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Overview
Equipment Details
Type: Washer
Manufacturer: Laundrylux
Make: Wascomat
Model Length: 4
Non-Compass/Compass Pro Control
For Set-O-Matic drop, set Dip Switch 7 to ON (?)
Associated Models
W620
W630
W640
W645
W650
W655
W675
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Item No. | Component | Notes |
1 | Power Connection Port | Utilizes the same power harnesses as the first generation FasCard reader. |
2 | Pulse Connection Port | Connection point for pulse machine start harnesses. |
3 | Coin 1 Connection Port | This is the connection point for the harness input associated with Coin 1. |
4 | Coin 2 Connection Port | This is the connection point for the harness input associated with Coin 2. |
5 | Serial Connection Port | This is the connection point for serial machine start harnesses. |
- Feed remaining harness ends through the mounting hole as described in the Touchscreen Reader Mounting Guide (F2 & F3).
- Connect the free end of the pulse start harnesses (white connector), connect to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500-84 Power Harness to port 1.
- Secure the FasCard reader to base as described in the Touchscreen Reader Mounting Guide (F2 & F3).
Machine Configuration
TODO
CCI Software Configuration
Machine Control | Pulse | Serial |
---|---|---|
Compass (Gen6) | SingleVend (Relay) / 42ms | Laundrylux Compass Washer |
Compass Pro (Gen7) | SingleVend (Relay) / 42msms | Laundrylux Compass Pro Washer |
Keltner - Pulse | SingleVend (Relay) / 1000ms | *NOT SUPPORTED* |
Rotary Timer - Pulse | SingleVend (Relay) / 2000ms | *NOT SUPPORTED* |
Set-O-Matic - Pulse | SingleVend (Relay) / 100ms | *NOT SUPPORTED* |
Additional Resources
- How to Program Address on a FasCard Reader
- FasCard Admin Site - Equipment Setup
- FasCard Admin Site - Machine Setup
- FasCard Admin Site - Pricing & Features Schedule
- F1 Reader Mounting Guide
- FasCard F2/F3 Reader Installation Guide - Front Mount
- FasCard Installation Videos
- FasCard Kit Installations - Machine Configurations & Related Documents