Skip to end of metadata
Go to start of metadata
You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 9
Next »
Overview
Equipment Details
Type: Tumble Dryer (Stack)
Manufacturer: Tolon
Make: Tolon
Model Length: 6
Associated Models
TRDS16
TRDS16U
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
I-M0203
Part #: C-6602-V2
Desc 1: F2, Large Vault Mount
Desc 2: Modified version
Qty: 1
Part #: C-6601
Desc 1: Spacer
Desc 2: F2 Dexter Vault Filler Plate
Qty: 1
Part #: C-0144
Desc 1: Screw
Desc 2: 8-32 x 2" - Flat
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Feed all reader harness ends through the open face of the Coin Vault.
Spread the C-6602 Vault Mount Bracket wings outward.
Feed the harness ends through the C-6602 Vault Mount Bracket.
Insert the C-6602 Vault Mount Bracket into the Coin Vault and ensure the inner tabs lock into place so it's secured in place.
Feed the remaining harness ends through both the C-6601 Filler Plate and C-5414 F2 Mounting Bracket.
Secure both the C-5414 F2 Mounting Bracket and C-6601 Filler Plate to the C-6602 Vault Mount Bracket with the C-0144 Screws.
I-M0216
Part #: C-6802
Desc 1: FLEX RF Reader Mounting Kit
Desc 2:
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
Instructions do not exist for Kit I-M0284
Connect Power
I-P0008
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500-84
Desc 1: Power Extension Harness
Desc 2: 84"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
Connect the C-5500-84 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0046
Part #: C-6360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Disconnect coin drop from factory machine harness.
Connect C-6360 Coin Sense Harness to the coin drop.
Connect red to red.
Connect green to brown.
Connect blue to blue.
Connect Machine Interface Harness
I-T0040
Part #: C-5256
Desc 1: Machine Start Harns (pulse)
Desc 2: 20" - Male taps, Rq. Female
Qty: 1
Connect the C-5256 Machine Start Harness to the harness originally connected to the coin drop.
Connect to the black and brown wires.
To prevent any potential electrical issues, apply electrical tape over the blue wire connector.
I-X0049
Part #:
Desc 1: Kit ID: I-X0049
Desc 2:
Qty: 0
Part #: C-6360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Part #: C-5262
Desc 1: Machine Start Harness
Desc 2: 40" - Male taps, Rq. Female
Qty: 1
Part #: C-6410
Desc 1: F3, SLV Stack Add On Dongle
Desc 2: Pulse / SingleVend
Qty: 1
Run C-5262 Machine Start Harness and C-6360 Coin Sense Harness to the lower pocket control board.
Connect C-5262 Machine Start Harness to the Coin 1 connection and the C-6360 Coin Sense Harness to the coin drop designated for the lower pocket.
Locate area to mount C-6410 Pulse Stack Add-On Board.
Must be close enough to reader mounting location to connect the harness to.
Must be on a surface that does not received direct exposure from any heating elements (If applicable.)
Clean mounting location to remove any dust and residue if needed.
Remove the sticker from the back of the C-6410 Pulse Stack Add-On Board to expose the adhesive and apply to the mounting location.
Connect the C-6410 Stack Add-on Board to port 5 (Serial Connection Port) on the card reader.
Connect the C-5262 Machine Start Harness connected to the lower pocket Machine Control Assembly to the J1 connection on the C-6410 Stack Add-on Board.
Connect the C-6360 Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the card reader.
Connect the C-6360 Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the card reader.
I-X0044
Part #:
Desc 1: Kit: I-X0044
Desc 2:
Qty: 0
Part #: C-6400
Desc 1: Stack Add On Board - SLV
Desc 2: F2 - Pulse / SingleVend
Qty: 1
Part #: C-5262
Desc 1: Machine Start Harness
Desc 2: 40" - Male taps, Rq. Female
Qty: 1
Part #: C-6360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Run C-5256 Machine Start Harness and C-6360 Coin Sense Harness to the lower pocket control board.
Connect C-6360 Coin Sense Harness to the coin drop for the lower pocket.
Connect red to red.
Connect green to brown.
Connect blue to blue.
Connect the C-5256 Machine Start Harness to the harness originally connected to the lower pocket’s coin drop.
Connect to the black and brown wires.
To prevent any potential electrical issues, apply electrical tape over the blue wire connector.
Connect the C-6400 Stack Add-on Board to port 5 (Serial Connection Port) on the card reader.
Connect the C-5256 Machine Start Harness connected to the lower pocket Machine Control Assembly to the J1 connection on the C-6400 Stack Add-on Board.
Connect the C-6360 Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the card reader.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
*NO NAME* | SingleVend (Relay) / 100ms | *NOT SUPPORTED* |