Skip to end of banner
Go to start of banner

Enabling serial communication on Continental washers

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Equipment Models

This document is valid for Continental washers with the add on serial daughter board.

Assumptions

This document assumes the installer is technically familiar with Continental Washers-Extractors.  This procedure is required to allow the host machine to communicate to CCI card reader with a serial interface, which supports multi-level pricing and cycle configuration from CCI LaundryCard and CCI FasCard systems.

Tools Required

  • No tools are required

Instructions 

  1. Open washer door

  2. Press and hold the 1 key until 'Cod' appears on the display.
  3. Press 1,2,3,4,1,2,3,4
  4. 'Pro' appears on the display, press the 2 key repetitively until 'nod' appears on the display
  5. Press the 1 key repetitively until 'Id-0- appears on the display
  6. Press the 2 key one time, 'Id-1' appears on the display
  7. Press the 1 key one time
  8. Press the Stop key

Video Tutorials