I-P0026
Part #: C-1098
Desc 1: 3M Dual Lock 1" wide
Desc 2: Use 4" strips for C-5602
Qty: 1
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Locate the 120v power lines in the machine. These wires are usually black and white and are located just inside the back of the panel. Use a voltage tester to confirm the correct wiring.
Apply the C-5101 Spade Taps to both the black and white power wires and clamping them down with pliers.
Plug the brown wire of the C-5336 Power Adapter Harness to the white/neutral wire tap and the blue wire to the black/L1 wire tap.
Locate a green chassis ground screw and loosen to insert the green wire from the C-5336 Power Adapter Harness and retighten.
Connect the 3-pin connector from the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.
Apply the C-1098 Velcro to the C-5602R1 Power Converter and secure inside the machine's panel.
Connect the 4-pin connector from the C-5500 Power Extension Harness to the C-5602R1 Power Converter.
Route the 3-pin connector from the C-5500 Power Extension Harness through the open card slot on the machine control panel.