Skip to end of metadata
Go to start of metadata
You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 3
Next »
Overview
Equipment Details
Type: Dryer
Manufacturer: LG
Make: LG
Model Length: Not Set
Titan-C Dryer
Associated Models
TLD1840CES
TLD1840CGD
TLD1840CGS
TLD1840CGW
TLD1840QGS
TLD1840QGW
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to Touchscreen Reader Mounting Guide (F2 & F3) for further instructions.
I-M0166
Part #: C-6923
Desc 1: Metercase Bracket
Desc 2: LG - Grey
Qty: 1
Part #: C-0923-ROD
Desc 1: Metercase Mounting Rod
Desc 2: LG
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove existing coin box and coin drop.
- Attach the C-5414 F2 Mounting Bracket to the C-6923 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.
- Run any card reader harnesses through the coin slot openings and the circular hole in the C-6923 Metercase Bracket.
Install the C-6923 Metercase Bracket into the front of the metercase and secure using the C-0923-ROD Metercase Mounting Rod from inside the metercase.
I-M0136
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to Touchscreen Reader Mounting Guide (F2 & F3) for further instructions.
Connect Power
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
- Use the C-5101 Spade Taps on the incoming power.
- Tap the L1 wire.
- Tap the N/L2 wire.
- Tap the Ground wire.
- Take the C-5210 Power Adapter Harness and connect the red tab connectors to the following wires:
- Connect the blue wire to the L1 wire.
- Connect the brown wire to the N/L2 wire.
- Connect the green/yellow wire to the Ground wire.
- Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connection on the C-5602R1 Power Converter.
- Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connection on the C-5500 Power Extension Harness.
Connect Coin Sense Harness
I-S0027
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: F2
Qty: 1
- Disconnect the Coin Drop from the Machine Control Assembly.
- Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0067
Part #:
Desc 1: KIT ID: I-S0067
Desc 2:
Qty: 0
Part #: C-6271
Desc 1: F2 Digicoin Sense Harness
Desc 2:
Qty: 1
- Disconnect the Coin Drop from the Machine Control Assembly.
- Connect the C-6271 Coin Sense Harness to the connector on the back of the Coin Drop.
Connect Machine Interface Harness
I-T0046
Part #: C-5272
Desc 1: Machine Start Harness
Desc 2: LG
Qty: 1
- Connect the C-5272 Machine Start Harness to the machine coin harness originally connected to the coin drop.
I-T0087
Part #: C-5273
Desc 1: 12 Pin Start Harness
Desc 2: LG
Qty: 1
- Connect the C-5273 Machine Start Harness to the 12-pin machine coin harness originally connected to the coin drop.
Connect and Mount Reader
- Feed remaining harness ends through the mounting hole.
- Connect the free end of the C-5272 or C-5273 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- (Coin and Card Installations Only) Connect the free end of the C-6250 or C-6271 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Titan-C Light - WiFi 2.0 Dryer | SingleVend (Relay) / 30ms | *NOT SUPPORTED* |