Install Mounting Hardware

Connect Power

Connect Coin Sense Harness

 I-S0054

Part #: C-6332

Desc 1: Coin Sense Harness (SA)

Desc 2: CGI EM

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6332 Coin Sense Harness to the harness connected to the Coin Drop.

    1. Connect the Red connector to the Coin Acceptor connection, where the coin drop was previously connected, on the Machine Control Assembly.

Connect Machine Interface Harness

 I-T0017

Part #: C-0114-MLV

Desc 1: Machine Start Harness

Desc 2: Continental

   Qty: 1

  1. Connect the C-0114-MLV Machine Start Harness to the middle X1 port on the serial communication board.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.

  2. Connect the free end of the C-0114-MLV Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. (Coin and Card Installation Only) Connect the free end of the C-6332 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  4. Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.

Machine Configuration

ProfitPlus Controls

  1. Connect the washer and open the door. The display will show door.

  2. Press and hold down key 1 until the Cod report appears on the display.

  3. Enter the access code into the menus by pressing the sequence of eight keys of the code without interruption. In basic configuration (when the machine is delivered) the access code to ADVANCED MODE is: 12341234.

  4. If the sequence entered is correct, the display will show Pro, corresponding to the first menu ADVANCED MODE.

  5. Keys 2 and 4 allow the selection of the precedent table menus. The menu selected is shown on the display following its keyword. To enter in it, press key 1 when displaying it.

  6. Navigate to Mod > ID and set value to '1'.

  7. Exit ADVANCE MODE.