Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Overview
Equipment Details
Type: Front Load Washer
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15
Associated Models
BFNBCFSG111TN01
BFNBCFSP112TW01
BFNBEFSP1110W01
BFNBEFSP111CW01
HFNBCFSG111TN01
HFNBCFSG112TN01
HFNBCFSG112TQ01
HFNBCFSP111TN01
HFNBCFSP112TW01
HFNBCRSP112TW01
SFNBCFSP112TW01
SFNBCRSP112TW01
SFNBXFSP112TW01
SFNBYRSP112TW01
SFNCCFSP111TW01
SFNLCF8G111TN01
SFNLCFSG111TN01
SFNLCFSG111TW01
SFNLCFSP111TN01
SFNLCFSP111TQ01
SFNLCFSP111TW01
SFNLGFSG111TN01
SFNLYFSG111TN01
SFNNCF8G1127N01
SFNNCFAG112TN01
SFNNCFSD112TN01
SFNNCFSG112TN01
SFNNCFSG112TW01
SFNNXFSP112TN01
SFNWCFSG112TN01
SFNWCFSG112TN11
SFNWCFSG172TN11
SFNWYFSG112TN01
SFNWYFSG112TW01
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
- Feed remaining harness ends through the mounting hole.
- (Pulse Machine Interface Harnesses Only) Connect the free end of the C-5300-NC Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- (Serial Communication / Serial Pulse Only) Connect the free end of the C-0110-TOP Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
- (Coin and Card Installations Only) Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
Machine Configuration
Power off the machine. Connect the C-0110-CP Jumper Plug to the H2 connection on the Machine Control Assembly. Power on the machine.MDC Controls
Power off the machine. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly. Power on the machine.Centurion Quantum Gold TLW Controls
CCI Software Configuration
Machine Control | Pulse | Serial |
---|---|---|
MDC (Vended) | SingleVend (MLV+) / 80ms | Alliance MDC Front Load Washer |
Quantum Gold (C4) | SingleVend (MLV+) / 80ms | Alliance Centurion Front Load Washer C4 - Quantum Gold |
Additional Resources
- How to Program Address on a FasCard Reader
- FasCard Admin Site - Equipment Setup
- FasCard Admin Site - Machine Setup
- FasCard Admin Site - Pricing & Features Schedule
- F1 Reader Mounting Guide
- FasCard F2/F3 Reader Installation Guide - Front Mount
- FasCard Installation Videos
- FasCard Kit Installations - Machine Configurations & Related Documents