Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Laundrylux
Make: Wascomat
Model Length: 3

Associated Models


W75

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

Connect Power

Connect Coin Sense Harness

 I-S0052

Part #: C-6389

Desc 1: Coin Sense Harness

Desc 2: Set-O-Matic

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6389 Coin Sense Harness to the harness connected to the Coin Drop.

 I-C0017

Part #: C-6380

Desc 1: Combination Harness (SA)

Desc 2: Keltner SR1-WIR 110-220v

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the 6-pin male connector from the C-6380 Coin Sense Harness to the 6-pin female connector on the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-C0017

Part #: C-6380

Desc 1: Combination Harness (SA)

Desc 2: Keltner SR1-WIR 110-220v

   Qty: 1

  1. Connect the 6-pin female connector from the C-6380 Machine Start Harness to the 6-pin male coin connector on the Machine Control Assembly.

Connect and Mount Reader

CCI Software Configuration

Machine ControlPulseSerial
Keltner - PulseSingleVend (Relay) / 1000ms*NOT SUPPORTED*
Rotary Timer - PulseSingleVend (Relay) / 3000ms*NOT SUPPORTED*
Set-O-Matic - PulseSingleVend (Relay) / 100ms*NOT SUPPORTED*