Skip to end of banner
Go to start of banner

3568 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Front Load Washer
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15

If equipped with electronic coin drop that uses existing H10 power connector, send I-P0007 power kit instead.

Associated Models


BFNBCASG113TN01
BFNBCASG113TW01
BFNBCASP113TW01
BFNBYAJP113TW01
BFNBYASP113TW01
HFGBYAGF113TW01
HFMBCASP113CW01
HFMBYASP113CW01
HFNBCAGS113TW01
HFNBCASG113TN01
HFNBCASG113TW01
HFNBCASG115TW01
HFNBCASP113TN01
HFNBCASP113TW01
HFNBCASP115TW01
HFNBCASP115TW02
HFNBCAST113TW01
HFNBCRSP115TW01
HFNBCRST115TW01
HFNBXASP113CW01
HFNBXASP115CW01
HFNBYAFP115CW01
HFNBYASP113CW01
HFNBYASP115CW01
HFNBYASP115TW01
HFNBYAST115CW01
HFNKCA8P116PW01
HFNKCA8P116TW01
HFNKCAF6116PW01
HFNKCAFG113TN01
HFNKCAFP116TW01
HFNKCAFT115TN01
HFNKCAPS116TW01
HFNKCASD115TN01
HFNKCASG113TN01
HFNKCASG113TN31
HFNKCASG113TN32
HFNKCASG113TW01
HFNKCASG115TN01
HFNKCASG115TN32
HFNKCASG115TW01
HFNKCASG116TN01
HFNKCASG116TW01
HFNKCASP113TN31
HFNKCASP113TN32
HFNKCASP115TN01
HFNKCASP115TN31
HFNKCASP115TW01
HFNKCASP116TN01
HFNKCASP116TW01
HFNKCAST116CW01
HFNKCASZ113TN01
HFNKDA8P116PW01
HFNKEAFG115TN01
HFNKXASG113CN01
HFNKXASG115CN01
HFNKXASG115CN32
HFNKXASG115CW01
HFNKXASP115CN01
HFNKXASP115CN32
HFNKXASP115CW01
HFNKYASG113CN01
HFNKYASG113CW01
HFNKYASG113TW01
HFNKYASG115CN01
HFNKYASG115CN31
HFNKYASG116CN01
HFNKYASP115CN01
HFNKYASP115CW01
HFNKYASP115TW01
HFNKYASP116CN01
HFNNCASG116TW01
HFNNYASG116TW01
PFNJCASG115TG01
PFNJCASG115TN01
PFNJCASP115TG01
PFNJXASP114TG01
PFNJXASP115TG01
SFNBCASG113TW01
SFNBCASP113TW01
SFNBCRSP113TW01
SFNBXASP113TW01
SFNBYRSP113TW01
SFNKCA8G1157W01
SFNNCAFG113TW01
SFNNCAFG115TN01
SFNNCAGS113TN01
SFNNCAS4116TW01
SFNNCASG113TN01
SFNNCASG113TW01
SFNNCASG115TN01
SFNNCASG115TW01
SFNNCASG116TN01
SFNNCASG116TW01
SFNNCASP113TN01
SFNNCASP113TW01
SFNNCASP114TW01
SFNNCASP115PW01
SFNNCASP115TN01
SFNNCASP115TW01
SFNNCASP116EW01
SFNNCASP116PW01
SFNNCASP116TN01
SFNNCASP116TW01
SFNNCAST115TW01
SFNNCAZP115TW01
SFNNCRSG115TW02
SFNNCRSP115TW02
SFNNCRSP116TW01
SFNNXASG113TW01
SFNNXASG115TN01
SFNNXASG115TW01
SFNNXASP113TN01
SFNNXASP113TW01
SFNNXASP115TW01
SFNNXASP116TW01
SFNNXRSP115TW02
SFNNYA8P115TW01
SFNNYAGS116PW01
SFNNYAGS116TW01
SFNNYAJP115TW01
SFNNYASG113TN01
SFNNYASP113TW01
SFNNYASP115TW01
SFNNYASP116TW01
SFNNYASP225TW01
SFNNYAST115TW01
SFNNYAST116TW01
SFNNYATP115TW01
SFNNYRSP115TW01
SFNNYRSP116TW01
SFNWCASG113TN01
SFNWCASG1151N01
SFNWCASG115TN01

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0119

Part #: C-1059

Desc 1: Nut

Desc 2: 10-32 - Kep

   Qty: 2

Part #: C-1070-W

Desc 1: Washer - Build: XCH

Desc 2: 1/4" x 1" O.D.

   Qty: 2

Part #: C-6765-W-R1

Desc 1: F2 Mounting Bracket

Desc 2: 10 Degree - White Finish

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin drop.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.

  3. Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  4. Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1 Metercase Bracket.

  5. Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.

Connect Power

 I-P0002

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the machine control assembly.

    1. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-6204-40 Power Adapter Harness (3-pin molex) to the F2 reader.

 I-P0023

Part #: C-6207

Desc 1: F2/F3, Alliance ACA Power

Desc 2:

   Qty: 1

  1. Connect the 2-pin connector from the C-6207 F2, ACA Power Harness to the 24v transformer behind the front control panel.

  2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the Coin 1 machine harness connected to the coin drop.

Connect Machine Interface Harness

 I-T0003

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Connect and Mount Reader

Machine Configuration

ACA Controls

  1. Locate the dip switch on the back of the machine's control board.

  2. Set dip switch 3 to the ON position. 

  3. Leave all other dip switches as is.

Titanium Controls

  1. Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control:

    Quantum Gold Pro (T4)

    Galaxy 600 Pro (T2)

    MDC II (T1)

    Regular & NormalHot & Blankets Cold

    Normal Hot & Perm Press Warm

  2. rAPid will be displayed on the control. Select the Prog option and then configure the following settings:

    1. Serial Payment Configuration (SErPAY): Card

    2. Card Enable (CArdEn): On

  3. Exit Manual Mode.

CCI Software Configuration

Machine ControlPulseSerial
Coin Slide Hybrid (Pulse)SingleVend (Relay) / -80ms*NOT SUPPORTED*
Galaxy 600 (A2)SingleVend (MLV+) / 80msAlliance ACA H7S Front Load Washer A2 - Galaxy 600
International (A3)SingleVend (MLV+) / 80msAlliance ACA H7S Front Load Washer A3 - International
MDC II (A1)SingleVend (MLV+) / 80msAlliance ACA H7S Front Load Washer A1 - MDC II
Quantum+ (A4)SingleVend (MLV+) / 80msAlliance ACA H7S Front Load Washer A4 - Quantum+
Titanium (T1)SingleVend (MLV+) / 80msAlliance Titanium Front Load Washer T1
Titanium (T2)SingleVend (MLV+) / 80msAlliance Titanium Front Load Washer T2
Titanium (T4)SingleVend (MLV+) / 80msAlliance Titanium Front Load Washer T4

  • No labels