Skip to end of banner
Go to start of banner

3577 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

ERROR: Unable to connect to 'InstallRef' database.

Source: Microsoft OLE DB Driver for SQL Server
Number: -2147467259
Description: Cannot open database "CCI_InstallRef" requested by the login. The login failed.

Install Mounting Hardware

Connect Power

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0012

Part #: C-0110-TOP

Desc 1: Machine Start Harness

Desc 2: 36" - Alliance Pre-ACA

   Qty: 1

Part #: C-0110-CP

Desc 1: Jumper Plug

Desc 2: Enables card mode on pre-ACA

   Qty: 1

  1. Connect the C-0110-TOP Machine Start Harness to the machine control assembly at:

    1. H5 for MDC controls.

    2. H4 for Centurion controls.

  2. (Serial Communication Setup Only) Replace the existing Alliance Jumper Plug with C-0110-CP Jumper Plug at:

    1. H2 for MDC controls.

    2. H6 for Centurion controls

Connect and Mount Reader

Machine Configuration

MDC Controls

  1. Power off the machine.

  2. Connect the C-0110-CP Jumper Plug to the H2 connection on the Machine Control Assembly.

  3. Power on the machine.

Centurion Quantum Gold TLW Controls

  1. Power off the machine.

  2. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.

  3. Power on the machine.

ERROR: Unable to connect to 'InstallRef' database.

Source: Microsoft OLE DB Driver for SQL Server
Number: -2147467259
Description: Cannot open database "CCI_InstallRef" requested by the login. The login failed.
  • No labels