Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Maytag
Make: Maytag
Model Length: 10

Associated Models


MHN33PDAWW
MHN33PDCGW
MHN33PDCWW
MHN33PDCWW0
MHN33PDCWW1
MHN33PDCWW2
MHN33PDCXW
MHN33PRCWW
MHN33PRCWW2

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

 I-M0006

Part #: C-5014

Desc 1: Reader Base & Gasket

Desc 2: F1

   Qty: 1

Part #: C-5027

Desc 1: Label

Desc 2: Credit Card Logo

   Qty: 1

Part #: C-5702

Desc 1: Chase Nipple

Desc 2: 3/4"

   Qty: 1

Part #: C-5703

Desc 1: Lock Nut

Desc 2: 3/4" - 102-S

   Qty: 1

Part #: C-5705

Desc 1: Screw

Desc 2: 8 x 1-1/2 Plastite

   Qty: 2

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0085

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-0303

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-5027

Desc 1: Label

Desc 2: Credit Card Logo

   Qty: 1

Part #: C-5771

Desc 1: Metercase Bracket

Desc 2: Coin Drop Ready Machines

   Qty: 1

  1. Remove coin drop and coin box.

  2. Insert the C-5771 Metercase Bracket over the front of the metercase. Attach using the C-0303 Topload Mounting Bolt from the inside of the metercase.

  3. Optional: Apply the C-5027 Label on or near the card reader for any accepted credit card issuers.

 I-M0122

Part #: C-0303

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-6911

Desc 1: F2 Metercase Bracket

Desc 2: Whirlpool - White

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin mechanism.

  2. Run reader harnesses through the metercase and out the opening where the coin mechanism was mounted.

  3. Attach the C-5414 Reader Bracket to the C-6911 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  4. Insert the reader harnesses through the hole in the C-6911 Metercase Bracket and then insert the bracket into the metercase opening.

  5. Secure the C-6911 Metercase Bracket to the metercase using the C-0301 Mounting Bolt.

 I-M0010

Part #: C-5801

Desc 1: F1 Reader Mounting Kit

Desc 2: Front

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F1 Reader Mounting Guide for further instructions.

 I-M0136

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0216

Part #: C-6802

Desc 1: FLEX RF Reader Mounting Kit

Desc 2:

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

Instructions do not exist for Kit I-M0238

 I-M0250

Part #: C-6802

Desc 1: FLEX RF Reader Mounting Kit

Desc 2:

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

 I-M0136

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Remove the (4) security torx retaining screws on the front of the machine.

  2. Remove the soap tray by pulling it out and pressing on the retaining tab in the rear of the tray.

  3. Locate and remove the (2) security torx screws inside the soap tray opening.

  4. Remove the final (2) torx screws to open the top cover.

  5. Locate a spot on top of the machine to mount the reader. Verify included harnesses will reach desired location without encountering interference from internal machine components. Mark the location using C-6700-TEMP Drill Template.

  6. Refer to F2 Reader Mounting Guide for instructions on drilling mounting holes and mounting the reader.

Connect Power

 I-P0007

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 2

Part #: C-5336

Desc 1: Power Adapter Harness

Desc 2: Dexter Stack

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the FasCard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

    1. 120vac: Connect the blue wire to L1 and the brown wire to N.

    2. 240vac: Connect the blue wire to L1 and the brown wire to L2.

    3. Secure the green wire to the ground screw.

  2. Connect the C-5336 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0020

Part #: C-5362

Desc 1: Coin Sense Harness

Desc 2: MLG

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-5362 Coin Sense Harness to the harness connected to the Coin Drop.

 I-S0048

Part #: C-6362

Desc 1: Coin Sense Harness

Desc 2: MLG

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6362 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0090

Part #: C-5364

Desc 1: Machine Start Harness

Desc 2: Maytag MFR

   Qty: 1

Part #: C-0126-MLV-EXT15

Desc 1: Extension Harness

Desc 2: Compass

   Qty: 1

  1. Connect the C-5364 Machine Start Harness to the Debit/AA3 connector on the Machine Control Assembly.

    1. If needed, use the C-0126-MLV-EXT15 Extension Harness to extend the C-5364 Machine Start Harness.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

MayTag AA3/Debit Connection Payment Pulse

  1. Enter Service Mode by activating the service switch.

  2. Locate Coin/Debit Option (J.) and set to Cd.

Enhanced Debit (Gen 2)

Enhanced Debit is self-selected when a Generation 2 card reader is installed in the dryer. The Ed option cannot be manually selected or deselected.