Skip to end of banner
Go to start of banner

3577 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Front Load Washer
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15

Associated Models


BFNBCFSG111TN01
BFNBCFSP112TW01
BFNBEFSP1110W01
BFNBEFSP111CW01
HFNBCFSG111TN01
HFNBCFSG112TN01
HFNBCFSG112TQ01
HFNBCFSP111TN01
HFNBCFSP112TW01
HFNBCRSP112TW01
SFNBCFSP112TW01
SFNBCRSP112TW01
SFNBXFSP112TW01
SFNBYRSP112TW01
SFNCCFSP111TW01
SFNLCF8G111TN01
SFNLCFSG111TN01
SFNLCFSG111TW01
SFNLCFSP111TN01
SFNLCFSP111TQ01
SFNLCFSP111TW01
SFNLGFSG111TN01
SFNLYFSG111TN01
SFNNCF8G1127N01
SFNNCFAG112TN01
SFNNCFSD112TN01
SFNNCFSG112TN01
SFNNCFSG112TW01
SFNNXFSP112TN01
SFNWCFSG112TN01
SFNWCFSG112TN11
SFNWCFSG172TN11
SFNWYFSG112TN01
SFNWYFSG112TW01

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

Connect Power

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Connect and Mount Reader

Machine Configuration

MDC Controls

  1. Power off the machine.

  2. Connect the C-0110-CP Jumper Plug to the H2 connection on the Machine Control Assembly.

  3. Power on the machine.

Centurion Quantum Gold TLW Controls

  1. Power off the machine.

  2. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.

  3. Power on the machine.

CCI Software Configuration

Machine ControlPulseSerial
MDC (Vended)SingleVend (MLV+) / 80msAlliance MDC Front Load Washer
Quantum Gold (C4)SingleVend (MLV+) / 80msAlliance Centurion Front Load Washer C4 - Quantum Gold

  • No labels