Overview
Equipment Details
Type: Tumble Dryer (Single)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 18
Associated Models
HT055NVCARBS6NC000
HT075LVC0RXS5NC000
HT075LVP0RXS5NC000
HT075LVX0RXS5NC000
HT075NVCARBS5NC000
HT075NVCARBS6NC000
HT075NVCARXS5NC000
HT075NVCARXS6NC000
HT075NVCARXS6NCC00
HT075NVL0RBS5NC000
HT075NVY0RXS6NC000
ST030NVCANBH4NC000
ST055NVCARBS5NC000
ST055NVCARBS6NC000
ST055NVCARXS60BA00
ST055NVEARBS4NC000
ST055NVY0RBS6NC000
ST075NVCANBH4NC000
ST075NVCANBS4NC000
ST075NVCARBH5NC000
ST075NVCARBS5NC000
ST075NVCARBS6NC000
ST075NVCARXS6NC000
ST075NVP0RXS6NC000
ST075NVY0RBS6NC000
ST075NVYANBS4NC000
Installation
Install Mounting Hardware
Connect Power
I-P0002
Part #: C-6204-40
Desc 1: Power Adapter Harness
Desc 2: F2, 12vDC Pow Harness - 40"
Qty: 1
Connect the C-6204-40 Power Adapter Harness to the H10 connection on the machine control board.
Secure the green wire beneath the ground screw.
Connect the opposite end of the C-6204-40 Power Adapter Harness (3-pin molex) into the back of the F1 Reader.
Connect Coin Sense Harness
I-S0027
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: F2
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
Alliance Touch Controls
Enter the service menu by touch and holding on the top-center of the touch screen for 3 seconds.
Enter password if required.
Configure the machine with the following settings:
Payment Settings:
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Quantum Touch (Midas) | SingleVend (MLV+) / 80ms | Alliance Quantum Touch Tumbler Dryer |