Skip to end of banner
Go to start of banner

3580 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Small Dryer (Stack)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15

6th character is panel type:
A - 10deg Front Control Panel
F - Flat Front Control Panel

Associated Models


HSEBCAGS116TW01
HSEBCAGW173TW01
HSEBYAGS173TW01
HSEBYAGW173TW01
HSEBYAGW176TW01
HSGBCAGS116TW01
HSGBCAGW113TW01
HSGBCAGW116TW01
HSGBYAGS113TW01
HSGBYAGS116TW01
HSGBYAGW113TW01
HSGBYAGW116TW01
KSEBXAGS176TW01
KSGBXAGS115TW01
KSGBXAGS176TW01
KSGSXAGS113TW01
SSENCAGS153TW01
SSENCAGS173TW01
SSENCAGW173TW01
SSENCFGS173TW01
SSENXAGW173TW01
SSENYAGS173TW01
SSENYAGS175TW01
SSENYAGS176TW01
SSENYAGW176TW01
SSENYFGS176TW01
SSENYFGW175TW01
SSENYFGW176TW01
SSGNCAGS113TW01
SSGNCAGS116TW01
SSGNCAGW113TW01
SSGNCFGS113TW01
SSGNCFGS116TW01
SSGNXAGS113TW01
SSGNXAGW113TW01
SSGNYAGS113TW01
SSGNYAGS116TW01
SSGNYAGW116TW01
SSGNYFGS113TW01
SSGNYFGS116TW01
SSGSXAGS113TW01

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

Connect Power

 I-P0002

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 Connection on the Machine Control Assembly.

  2. Connect the green wire to a chassis ground.

  3. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

 I-S0031

Part #: C-6253

Desc 1: Coin Sense Harness

Desc 2: 28"

   Qty: 1

  1. Locate the micro switch on the coin slide assembly for the upper pocket.

  2. Disconnect the harness connected to the microswitch and connect C-6253 Coin Sense Harness to the spade tabs on the micro switch.

Connect Machine Interface Harness

 I-T0049

Part #: C-5300-NC

Desc 1: Machine Start Harness

Desc 2: Aliiance - Normally Closed

   Qty: 1

  1. Connect the C-5300-NC Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.

Extras

 I-X0008

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: can use C-5240-144

   Qty: 1

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: can use C-6250-144

   Qty: 1

Part #: C-6401

Desc 1: Stack Add On Board - MLV

Desc 2: Serial / MultiVend

   Qty: 1

  1. Run C-5240 Machine Start Harness and C-6250 Coin Sense Harness to the second Machine Control Assembly.

  2. Connect C-5240 Machine Start Harness to the H3 connection and the C-6250 Coin Sense Harness to the Coin 1 connection on the second Machine Control Assembly.

  3. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.

    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.

    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

  4. Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.

  5. Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.

 I-X0019

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: can use C-5240-144

   Qty: 1

Part #: C-6401

Desc 1: Stack Add On Board - MLV

Desc 2: Serial / MultiVend

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board on the lower pocket control.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

ACA Controls

  1. Locate the dip switch on the back of the machine's control board.

  2. Set dip switch 3 to the ON position. 

  3. Leave all other dip switches as is.

Titanium Controls

  1. Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control:

    Quantum Gold Pro (T4)

    Galaxy 600 Pro (T2)

    MDC II (T1)

    High Temp & Med TempHigh Temp & Med Temp

    High Temp & Med Temp

  2. rAPid will be displayed on the control. Select the Prog option and then configure the following settings:

    1. Serial Payment Configuration (SErPAY): Card

    2. Card Enable (CArdEn): On

  3. Exit Manual Mode.

CCI Software Configuration

Machine ControlPulseSerial
Coin Slide Hybrid (Pulse)SingleVend (Relay) / 80ms*NOT SUPPORTED*
MDC II (A1)SingleVend (MLV+) / 80msAlliance ACA H7S Small Dryer A1 - MDC II
Quantum+ (A4)SingleVend (MLV+) / 80msAlliance ACA H7S Small Dryer A4 - Quantum+
Titanium (T1)SingleVend (MLV+) / 80msAlliance Titanium Small Dryer T1
Titanium (T4)SingleVend (MLV+) / 80msAlliance Titanium Small Dryer T4

  • No labels