LaundryCard X-Changers are in constant need of maintenance and cleaning, similar to most equipment within the laundry business. X-Changer cleaning and preventative maintenance are necessary to keep the X-Changer and its internal components operating smoothly. This document is intended to guide the reader on how to properly maintain, clean, and manage their X-Changer hardware.
Contact us!
At any point, feel free to contact CCI Technical Support for any issues, concerns, or questions that may come up. You can reach them immediately by calling 630-930-5115, option 2. You can also reach them by email at support@laundrycard.com.
LITE X-Changer systems
For information about how to clean your LITE X-Changer cabinet, please visit Lite System Preventive Maintenance for details.
Cleaning schedule
Component | Frequency of cleaning | Supplied needed | Recommended maintenance and cleaning | Additional comments | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cabinet door & shell | Annually |
|
| N/A | ||||||||||
Fan | Once a month |
|
| Electronic components attract lint, which causes overheating. Use compressed air externally & the small brush internally for optimal results.
| ||||||||||
Touchscreen monitor | Bi-monthly (every two months) |
|
Caution Never spray anything directly onto the touchscreen monitor. It is suggested to lightly moisten the lint-free cloth and wipe the monitor gently. | If you wish to calibrate the touchscreen after cleaning it, please follow our Touchscreen Calibration guide. | ||||||||||
Dell computer | Bi-annually (twice a year) |
| N/A | Please see Computer Preventive Maintenance for details about cleaning the internal and external components of the Dell PC. | ||||||||||
Control Head(s) | Bi-annually (twice a year) |
|
| Please see Control Head Preventive Maintenance for additional details about preventative maintenance for the control head. | ||||||||||
Cabinet & store cabling | Bi-annually (twice a year) |
|
| |||||||||||
Tripp-Lite battery backup & surge protectors | Annually (once a year) |
|
| Please see Tripp-lite Battery Backup Preventive Maintenance for additional details about preventative maintenance for the Tripp-Lite UPS. | ||||||||||
Card dispenser | Every two months |
|
| If the card dispenser belts are worn out, please contact the manufacturer at the number below: Asahi Seiko | ||||||||||
Bill Note Acceptor (BNA) | Monthly, or as needed |
|
| If the BNA belts are worn out, please contact the manufacturer at the number below: MEI Bill Acceptor (Crane PI): Pyramid Bill Acceptor: Please see Bill Acceptor Preventive Maintenance and Troubleshooting for additional details about preventative maintenance for the BNA. | ||||||||||
LaundryCard card readers | Bi-monthly (twice a month), or as needed |
|
| |||||||||||
Barcode scanner | Every two months |
|
| Please see Barcode Scanner Preventive Maintenance for additional details about preventative maintenance for the barcode scanner. |