Overview
Equipment Details
Type: Washer
Manufacturer: Whirlpool
Make: Whirlpool
Model Length: 9 to 10
Card Only Model
Associated Models
CHW9160GW0
CHW9160GW1
Installation
Removing the Front Panel
Remove the (4) security torx retaining screws on the front of the machine.
Remove the soap tray by pulling it out and pressing on the retaining tab in the rear of the tray.
Locate and remove the (2) security torx screws inside the soap tray opening.
Remove the final (2) torx screws to open the top cover.
Install Mounting Hardware
I-M0010
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F1 Reader Mounting Guide for further instructions.
I-M0136
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0250
Part #: C-6802
Desc 1: FLEX RF Reader Mounting Kit
Desc 2:
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
Connect Power
I-P0007
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the FasCard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
120vac: Connect the blue wire to L1 and the brown wire to N.
240vac: Connect the blue wire to L1 and the brown wire to L2.
Secure the green wire to the ground screw.
Connect the C-5336 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Machine Interface Harness
I-T0004
Part #: C-5364
Desc 1: Machine Start Harness
Desc 2: Maytag MFR
Qty: 1
Connect the C-5364 Machine Start Harness to the AA3 (Debit) connector on the Machine Control Assembly.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
Enhanced Debit (Gen 2)
Enhanced Debit is self-selected when a Generation 2 card reader is installed in the dryer. The Ed option cannot be manually selected or deselected.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Gen2 | SingleVend (MLV+) / 24ms | Maytag Gen2 M16 Front-Load Washer |