Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Equipment Details
Type: Small Dryer (Stack)
Manufacturer: Alliance
Make: Speed Queen
Model Length: 8
On this page
Associated Models
HSET17WF
SSE107WF
SSE907WF
SSE917WF
SSET07WF
SSG109WF
SSG119WF
SSG909WF
SSGT09WF
SSGT19WF
SSGY09WF
SSGY19WF
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
- Feed remaining harness ends through the mounting hole.
- (Pulse Start Harness Only) Connect the free end of the C-5256 or C-5300-NC Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- (Serial Start Harness Only) Connect the free end of the C-0110-TOP Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
- (Coin and Card Installation Only) Connect the free end of the C-5250 or C-5253 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Machine Configuration
Power off the machine. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly. Power on the machine.MDC Controls
CCI Software Configuration
Machine Control | Pulse | Serial |
---|---|---|
CAM Timer | *NOT SUPPORTED* | *NOT SUPPORTED* |
Coin Slide Hybrid (Pulse) | SingleVend (Relay) / 500ms | *NOT SUPPORTED* |
EDC | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
MDC (Vended) | SingleVend (MLV+) / 80ms | Alliance MDC Small Dryer |
NetMaster | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
Additional Resources
- How to Program Address on a FasCard Reader
- FasCard Admin Site - Equipment Setup
- FasCard Admin Site - Machine Setup
- FasCard Admin Site - Pricing & Features Schedule
- F1 Reader Mounting Guide
- FasCard F2/F3 Reader Installation Guide - Front Mount
- FasCard Installation Videos
- FasCard Kit Installations - Machine Configurations & Related Documents