cci-readerinstall-kit |
---|
|
Remove existing coin box.
Remove Vault Switchand bridge the wires previously connected to the Vault Switchwith the C-5365 Bypass Harness.Bend the side tabs of theC-6602Vault Bracketoutward and install into the coin vault. The tabs should snap into place securing the bracket.Arrange both the C-5414 Mounting Bracket and the C-0906 Spacer so the smaller screw holes align. Secure both to the C-6601 Vault Mount so that the C-0906 Spacer is between the machine panel and the C-5414 Mounting Bracket.Apply the C-5033 Label over the coin drop opening.
...
cci-readerinstall-kit |
---|
|
Tap power as described in the document by connecting theC-5336Power Adapter Harnessto the power distribution panel inside the machine.120vac: Connect the blue wire to L1 and the brown wire to N using theC-5101Spade Taps.240vac: Connect the blue wire to L1 and the brown wire to L2 using theC-5101Spade Taps.Secure the green wire beneath the ground screw.
Connect the opposite end of theC-5336Power Adapter Harnessto theC-5602R1Power Converter.Connect theC-5500Power Extension Harness to the appropriate connector on theC-5602R1Power Converter. The remaining cable end connects to the FasCard reader.
...
...
...
Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
Machine Settings
Liquid Soap Supply: Enabled
Payment Settings:
Enable Types: Disable all payment types
Coin Options: Single
Coin 1 Value: Intended Vend Price
Coin 2 Value: Intended Vend Price
Serial Payment System: Disabled
On the FasCard Admin site, create a SingleVend equipment type with the following settings:
Mode: Simple
Pulse Length: 1000
Pulse Interval: 250
Pulse Type: Relay
Sensor Input: Required Off
Show Remaining Time: Disabled
Cycle Time: 600 Seconds
# Pulses: 1