Overview
Equipment Details
Type: Washer Extractor
Manufacturer: Alliance
Make: Huebsch
Model Length: 18
Associated Models
HYT020VCAHXUB0C0BA
HYT020VX0HXUB0C0BA
HYT020VX0HXUB0C0FQ
HYT030VCAHXUB0C0BA
HYT030VX0HXUB0C0BA
HYT030VX0HXUB0C0FQ
HYT030VX0HXUB0X0BA
HYT040VCAHXUB0C0BA
HYT040VCAHXUB0E0BA
HYT040VX0HXUB0E0FQ
HYT055VCAHXUB0E0BA
HYT055VCAHXUB0X0BA
HYT055VX0HXUB0E0BA
HYT055VX0HXUB0E0FQ
HYT070VCAHXUB0C0BA
HYT070VCAHXUB0E0BA
HYT070VX0HXUB0E0FQ
SYT020VCAHXUB0C0BA
SYT020VX0HXUB0C0BA
SYT030VCAHXUB0C0FQ
SYT040VCAHXUB0E0BA
SYT040VX0HXUB0E0BA
SYT055VX0HXUB0E0BA
Installation
Install Mounting Hardware
Connect Power
I-P0007
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5336 Power Adapter Harness to the power distribution panel inside the machine.
120vac: Connect the blue wire to L1 and the brown wire to N using the C-5101 Spade Taps.
240vac: Connect the blue wire to L1 and the brown wire to L2 using the C-5101 Spade Taps.
Secure the green wire beneath the ground screw.
Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0018
Part #: C-5360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.
Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.
Connect the C-5360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.
I-S0046
Part #: C-6360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.
Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.
Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.
Connect Machine Interface Harness
I-T0003
Part #: C-5240
Desc 1: Machine Start Harness
Desc 2: Alliance ACA
Qty: 1
Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board.
I-T0086
Part #: C-5265
Desc 1: Machine Start Harness
Desc 2: Alliance MC10 Control
Qty: 1
Part #: C-5266
Desc 1: 6" 18 AWG wire
Desc 2: Jumper for ALS MC10 Control
Qty: 1
Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.
Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.
Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)
Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
Singlevend - Coin Pulse
Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
Machine Settings
Liquid Soap Supply: Enabled
Payment Settings:
Enable Types: Disable all payment types
Coin Options: Single
Coin 1 Value: Intended Vend Price
Coin 2 Value: Intended Vend Price
Serial Payment System: Disabled
On the FasCard Admin site, create a SingleVend equipment type with the following settings:
Mode: Simple
Pulse Length: 1000
Pulse Interval: 250
Pulse Type: Relay
Sensor Input: Required Off
Show Remaining Time: Disabled
Cycle Time: 600 Seconds
# Pulses: 1
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
MC10 | SingleVend (Relay) / 1000ms | Alliance Quantum Touch Washer Extractor |