Install Mounting Hardware

Connect Power

 I-P0007

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 2

Part #: C-5336

Desc 1: Power Adapter Harness

Desc 2: Dexter Stack

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5336 Power Adapter Harness to the power distribution panel inside the machine.

    1. 120vac: Connect the blue wire to L1 and the brown wire to N using the C-5101 Spade Taps.

    2. 240vac: Connect the blue wire to L1 and the brown wire to L2 using the C-5101 Spade Taps.

    3. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0018

Part #: C-5360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-5360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

 I-S0046

Part #: C-6360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

ERROR: Unable to connect to 'InstallRef' database.

Source: Microsoft OLE DB Driver for SQL Server
Number: -2147467259
Description: Cannot open database "CCI_InstallRef" requested by the login. The login failed.
ERROR: Unable to connect to 'InstallRef' database.

Source: Microsoft OLE DB Driver for SQL Server
Number: -2147467259
Description: Cannot open database "CCI_InstallRef" requested by the login. The login failed.

Machine Configuration

Singlevend - Coin Pulse

  1. Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)

    1. Machine Settings

      1. Liquid Soap Supply: Enabled

    2. Payment Settings:

      1. Enable Types: Disable all payment types

      2. Coin Options: Single

      3. Coin 1 Value: Intended Vend Price

      4. Coin 2 Value: Intended Vend Price

      5. Serial Payment System: Disabled

  2. On the FasCard Admin site, create a SingleVend equipment type with the following settings:

    1. Mode: Simple

    2. Pulse Length: 1000

    3. Pulse Interval: 250

    4. Pulse Type: Relay

    5. Sensor Input: Required Off

    6. Show Remaining Time: Disabled

    7. Cycle Time: 600 Seconds

    8. # Pulses: 1