Overview
Equipment Details
Type: Other
Manufacturer: N/A
Make: [VARIES]
Model Length: Not Set
Associated Models
DOOR
Installation
Install Mounting Hardware
I-M0034
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-0801
Desc 1: Mounting Bracket
Desc 2: Door - painted black
Qty: 1
- Place the C-0801 Mounting Bracket at the desired mounting location. Align the bracket so the two unthreaded holes are at the top and bottom of the bracket.
- Using the C-0801 Mounting Bracket, mark the top and bottom holes for mounting it to the surface. Then mark the large central opening for inserting the LaundryCard reader and running required harnesses.
- Cut open the large central opening in the surface, then use material appropriate fasteners (Not Provided.) to secure the C-0801 Mounting Bracket to the surface.
I-M0068
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-5700
Desc 1: Mounting Bracket
Desc 2: Surface Mount
Qty: 1
- Place the C-5700-TEMP Drill Template on the desired mounting location.
- Mark hole "D" for the pilot hole to run the harnesses to the reader. Mark "C" and "E" holes to provide mounting points for the reader bracket.
- Use a 1-1/8" hole saw to drill a hole at position "D".
- Place and align C-5700 F1 Mounting Bracket so that the center hole aligns with hole "D" and the two holes immediately to the left and right align with the holes marked for "C" and "E".
- Using material appropriate fasteners (Not Provided.), secure the C-5700 F1 Mounting Bracket to the surface using points "C" and "E".
- Optional: If accepting credit cards, apply the C-5027 Label on or near the F1 card reader for applicable credit cards.
I-M0110
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
- Place the C-6700-TEMP Drill Template on the desired mounting location.
- Mark hole "C" for the pilot hole to run the harnesses to the reader. Mark "D" and "E" holes to provide mounting points for the reader bracket.
- Use a 1-1/8" hole saw to drill a hole at position "C".
- Place and align C-5414 F2 Mounting Bracket so that the center hole aligns with hole "C" and the two holes immediately to the left and right align with the holes marked for "D" and "E".
- Using material appropriate fasteners (Not Provided.), secure the C-5414 F2 Mounting Bracket to the surface using points "D" and "E".
Connect Power
I-P0011
Part #: C-5200-72
Desc 1: 72" Power Adapter Harness
Desc 2: 72"
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Connect the C-5200-72 Powerline Adapter Harness to an 120v electrical outlet.
- Connect the white, 3-pin connector from the C-5200-72 Powerline Adapter Harness to the matching end on the C-5602R1 Power Converter.
- Connect the 4-pin connector from the C-5500 Power Extension Harness to the matching end on the C-5602R1 Power Converter.
Connect Machine Interface Harness
I-T0040
Part #: C-5256
Desc 1: Machine Start Harns (pulse)
Desc 2: 20" - Male taps, Rq. Female
Qty: 1
- Connect the one of the ends of the C-5256 Machine Start Harness to the positive terminal from the door strike power source. Connect the other spade connector to the positive terminal on the door strike.
- Note: Depending on the door strike installed, spade terminals may not be available or may be too far apart for the harness to reach. In this case, cut the ends of the C-5256 Machine Start Harness and then cut and splice into the positive lead wire (In any pairing.).
- The negative lead from the door strike power source should remain connected to the negative terminal on the door strike.
- Note: If the door strike requires a normally closed circuit instead of a normally open one, move the wire in the 6th position to the 4th position on the C-5256 Machine Start Harness.
Connect and Mount Reader
LaundryCard
- Feed remaining harness ends through the mounting hole.
- Connect the free end of the C-5256 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracket using included hardware and cover screws using C-0015 Label.
F1 Reader
- Feed remaining harness ends through the mounting hole.
- Connect the free end of the C-5256 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
F2,F3,Flex,FlexRF
- Feed remaining harness ends through the mounting hole.
- Connect the free end of the C-5256 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
*NO NAME* | SingleVend (Relay) / ANYms | *NOT SUPPORTED* |