0114 Reader Install Guide

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Other
Manufacturer: N/A
Make: [VARIES]
Model Length: Not Set

Associated Models


DOOR

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Connect Power

 I-P0011

Part #: C-5200-72

Desc 1: 72" Power Adapter Harness

Desc 2: 72"

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Connect the C-5200-72 Powerline Adapter Harness to an 120v electrical outlet.

  2. Connect the white, 3-pin connector from the C-5200-72 Powerline Adapter Harness to the matching end on the C-5602R1 Power Converter.

  3. Connect the 4-pin connector from the C-5500 Power Extension Harness to the matching end on the C-5602R1 Power Converter.

Connect Machine Interface Harness

 I-T0040

Part #: C-5256

Desc 1: Machine Start Harns (pulse)

Desc 2: 20" - Male taps, Rq. Female

   Qty: 1

  1. Connect the one of the ends of the C-5256 Machine Start Harness to the positive terminal from the door strike power source. Connect the other spade connector to the positive terminal on the door strike.

    1. Note: Depending on the door strike installed, spade terminals may not be available or may be too far apart for the harness to reach. In this case, cut the ends of the C-5256 Machine Start Harness and then cut and splice into the positive lead wire (In any pairing.).

  2. The negative lead from the door strike power source should remain connected to the negative terminal on the door strike.

  3. Note: If the door strike requires a normally closed circuit instead of a normally open one, move the wire in the 6th position to the 4th position on the C-5256 Machine Start Harness.