Overview
Equipment Details
Type: Small Dryer (Single)
Manufacturer: Whirlpool
Make: Whirlpool
Model Length: 10
Associated Models
CED9050AWO
CGD9050AW0
CGD9050AW1
Installation
Install Mounting Hardware
I-M0099
Part #: C-0301
Desc 1: Topload Mounting Bolt
Desc 2:
Qty: 1
Part #: C-5771
Desc 1: Metercase Bracket
Desc 2: Coin Drop Ready Machines
Qty: 1
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Remove existing coin drop and coin box from the metercase.
Run the C-5500 Power Extension Harness and C-5364 Machine Start Harness through the metercase and then through the circular opening in the C-5771 Metercase Bracket.
Insert the C-5771 Metercase Bracket into the metercase and secure from the inside using the C-0301 Metercase Mounting Bolt.
Optional: Apply the C-5027 Label on or around the F1 reader for any accepted credit card issuers.
I-M0142
Part #: C-5800
Desc 1: F1 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F1 Reader Mounting Guide for further instructions.
Connect Power
I-P0007
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Locate the incoming power cables in the rear of the machine. This should include a white, black and green wire.
Use the C-5101 Spade Taps to tap the black (L1) and white (Neutral) wires.
Attach the spade ends of the C-5336 Power Adapter Harness to the taps. Blue to black, and Brown to White.
Attach the Green ground wire from the C-5336 Power Adapter Harness to a nearby chassis ground screw.
Connect the 3-pin connector from the C-5336 Power Adapter Harness to the 3-pin connector on the C-5602R1 Power Converter.
Connect the 4-pin connector from the C-5602R1 Power Converter to the 4-pin connector on the C-5500 Power Extension Harness.
Mount the C-5602R1 Power Converter in the machine by using zip ties to secure it to the machine's wire harness.
Connect Coin Sense Harness
I-S0020
Part #: C-5362
Desc 1: Coin Sense Harness
Desc 2: MLG
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5362 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0004
Part #: C-5364
Desc 1: Machine Start Harness
Desc 2: Maytag MFR
Qty: 1
Connect the C-5364 Machine Start Harness to the AA3 (Debit) connector on the Machine Control Assembly.
No EXTRAS kits exist for this equipment.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
Enter Service Mode and navigate to J option.
Set option to J.d.
Exit Service Mode.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Gen1 | SingleVend (MLV+) / 24ms | *NOT SUPPORTED* |