Skip to end of banner
Go to start of banner

3638 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer Extractor
Manufacturer: Alliance
Make: Huebsch
Model Length: 18

Associated Models

HYT020VCAHXUB0C0BA
HYT020VX0HXUB0C0BA
HYT020VX0HXUB0C0FQ
HYT030VCAHXUB0C0BA
HYT030VX0HXUB0C0BA
HYT030VX0HXUB0C0FQ
HYT030VX0HXUB0X0BA
HYT040VCAHXUB0C0BA
HYT040VCAHXUB0E0BA
HYT040VX0HXUB0E0FQ
HYT055VCAHXUB0E0BA
HYT055VCAHXUB0X0BA
HYT055VX0HXUB0E0BA
HYT055VX0HXUB0E0FQ
HYT070VCAHXUB0C0BA
HYT070VCAHXUB0E0BA
HYT070VX0HXUB0E0FQ
SYT020VCAHXUB0C0BA
SYT020VX0HXUB0C0BA
SYT030VCAHXUB0C0FQ
SYT040VCAHXUB0E0BA
SYT040VX0HXUB0E0BA
SYT055VX0HXUB0E0BA

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

Connect Power

Connect Coin Sense Harness

 I-S0018

Part #: C-5360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-5360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

 I-S0046

Part #: C-6360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

Connect Machine Interface Harness

 I-T0003

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board.

 I-T0086

Part #: C-5265

Desc 1: Machine Start Harness

Desc 2: Alliance MC10 Control

   Qty: 1

Part #: C-5266

Desc 1: 6" 18 AWG wire

Desc 2: Jumper for ALS MC10 Control

   Qty: 1

  1. Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.

  2. Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.

  3. Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)

  4. Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)

    C-5265 SoapLink Wiring Ref-20240125-044427.png

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

Machine Configuration

Singlevend - Coin Pulse

  1. Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)

    1. Machine Settings

      1. Liquid Soap Supply: Enabled

    2. Payment Settings:

      1. Enable Types: Disable all payment types

      2. Coin Options: Single

      3. Coin 1 Value: Intended Vend Price

      4. Coin 2 Value: Intended Vend Price

      5. Serial Payment System: Disabled

  2. On the FasCard Admin site, create a SingleVend equipment type with the following settings:

    1. Mode: Simple

    2. Pulse Length: 1000

    3. Pulse Interval: 250

    4. Pulse Type: Relay

    5. Sensor Input: Required Off

    6. Show Remaining Time: Disabled

    7. Cycle Time: 600 Seconds

    8. # Pulses: 1

  • No labels