Skip to end of banner
Go to start of banner

3638 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer Extractor
Manufacturer: Alliance
Make: Huebsch
Model Length: 18

Associated Models

HYT020VCAHXUB0C0BA
HYT020VX0HXUB0C0BA
HYT020VX0HXUB0C0FQ
HYT030VCAHXUB0C0BA
HYT030VX0HXUB0C0BA
HYT030VX0HXUB0C0FQ
HYT030VX0HXUB0X0BA
HYT040VCAHXUB0C0BA
HYT040VCAHXUB0E0BA
HYT040VX0HXUB0E0FQ
HYT055VCAHXUB0E0BA
HYT055VCAHXUB0X0BA
HYT055VX0HXUB0E0BA
HYT055VX0HXUB0E0FQ
HYT070VCAHXUB0C0BA
HYT070VCAHXUB0E0BA
HYT070VX0HXUB0E0FQ
SYT020VCAHXUB0C0BA
SYT020VX0HXUB0C0BA
SYT030VCAHXUB0C0FQ
SYT040VCAHXUB0E0BA
SYT040VX0HXUB0E0BA
SYT055VX0HXUB0E0BA

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to Touchscreen Reader Mounting Guide (F2 & F3) for further instructions.

 I-M0125

Part #: C-0144

Desc 1: Screw

Desc 2: 8-32 x 2" - Flat

   Qty: 2

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-6601

Desc 1: Spacer

Desc 2: F2 Dexter Vault Filler Plate

   Qty: 1

Part #: C-6602-V2

Desc 1: F2, Large Vault Mount

Desc 2: Modified version

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

  1. Remove existing coin box.

  2. Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
  3. Bend the side tabs of the C-6602 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Arrange both the C-5414 Mounting Bracket and the C-0906 Spacer so the smaller screw holes align. Secure both to the C-6601 Vault Mount so that the C-0906 Spacer is between the machine panel and the C-5414 Mounting Bracket.
  5. Apply the C-5033 Label over the coin drop opening.

Connect Power

 I-P0007

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 2

Part #: C-5336

Desc 1: Power Adapter Harness

Desc 2: Dexter Stack

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5336 Power Adapter Harness to the power distribution panel inside the machine.

    1. 120vac: Connect the blue wire to L1 and the brown wire to N using the C-5101 Spade Taps.

    2. 240vac: Connect the blue wire to L1 and the brown wire to L2 using the C-5101 Spade Taps.

    3. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0046

Part #: C-6360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.
    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.
  2. Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

Connect Machine Interface Harness

 I-T0086

Part #: C-5265

Desc 1: Machine Start Harness

Desc 2: Alliance MC10 Control

   Qty: 1

Part #: C-5266

Desc 1: 6" 18 AWG wire

Desc 2: Jumper for ALS MC10 Control

   Qty: 1

  1. Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.
  2. Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.
  3. Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)
  4. Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.
  1. Feed remaining harness ends through the mounting hole as described in the Touchscreen Reader Mounting Guide (F2 & F3).
  2. Connect the free end of the C-5265 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-6360 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the Touchscreen Reader Mounting Guide (F2 & F3).

Machine Configuration

Singlevend - Coin Pulse

  1. Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
    1. Machine Settings
      1. Liquid Soap Supply: Enabled
    2. Payment Settings:
      1. Enable Types: Disable all payment types
      2. Coin Options: Single
      3. Coin 1 Value: Intended Vend Price
      4. Coin 2 Value: Intended Vend Price
      5. Serial Payment System: Disabled
  2. On the FasCard Admin site, create a SingleVend equipment type with the following settings:
    1. Mode: Simple
    2. Pulse Length: 1000
    3. Pulse Interval: 250
    4. Pulse Type: Relay
    5. Sensor Input: Required Off
    6. Show Remaining Time: Disabled
    7. Cycle Time: 600 Seconds
    8. # Pulses: 1

  • No labels