Overview
Equipment Details
Type: Washer Extractor
Manufacturer: Alliance
Make: Huebsch
Model Length: 18
Associated Models
HYT020VCAHXUB0C0BA
HYT020VX0HXUB0C0BA
HYT020VX0HXUB0C0FQ
HYT030VCAHXUB0C0BA
HYT030VX0HXUB0C0BA
HYT030VX0HXUB0C0FQ
HYT030VX0HXUB0X0BA
HYT040VCAHXUB0C0BA
HYT040VCAHXUB0E0BA
HYT040VX0HXUB0E0FQ
HYT055VCAHXUB0E0BA
HYT055VCAHXUB0X0BA
HYT055VX0HXUB0E0BA
HYT055VX0HXUB0E0FQ
HYT070VCAHXUB0C0BA
HYT070VCAHXUB0E0BA
HYT070VX0HXUB0E0FQ
SYT020VCAHXUB0C0BA
SYT020VX0HXUB0C0BA
SYT030VCAHXUB0C0FQ
SYT040VCAHXUB0E0BA
SYT040VX0HXUB0E0BA
SYT055VX0HXUB0E0BA
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
I-M0010
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F1 Reader Mounting Guide for further instructions.
I-M0060
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Part #: C-0133
Desc 1: Standoff
Desc 2: 8-32" x 1-1/2" - Hex
Qty: 2
Part #: C-0140
Desc 1: Screw
Desc 2: 8-32 x 3/4" - Cap
Qty: 2
Part #: C-0936
Desc 1: Vault Mount Bracket
Desc 2:
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Remove existing coin box and coin drop.
Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
Bend the side tabs of the C-0936 Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.
Attach the C-0133 Standoffs to the Bracket.
Apply the C-0033 Label over the coin drop opening.
I-M0081
Part #: C-0133
Desc 1: Standoff
Desc 2: 8-32" x 1-1/2" - Hex
Qty: 2
Part #: C-0144
Desc 1: Screw
Desc 2: 8-32 x 2" - Flat
Qty: 2
Part #: C-0936
Desc 1: Vault Mount Bracket
Desc 2:
Qty: 1
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Remove existing coin box and coin drop.
Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
Bend the side tabs of the C-0936 Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.
Attach the C-0133 Standoffs to the Bracket.
Attach reader to C-0936 Vault Mount Bracket using C-0144 Screws.
Apply C-5033 Label over the coin drop opening.
Optional: Apply C-5027 Label on or near the reader for any accepted credit card issuers.
I-M0125
Part #: C-0144
Desc 1: Screw
Desc 2: 8-32 x 2" - Flat
Qty: 2
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Part #: C-6601
Desc 1: Spacer
Desc 2: F2 Dexter Vault Filler Plate
Qty: 1
Part #: C-6602-V2
Desc 1: F2, Large Vault Mount
Desc 2: Modified version
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Part #: C-5033
Desc 1: Label
Desc 2: 4-5/8" x 3-1/2"
Qty: 1
Remove existing coin box.
Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
Bend the side tabs of the C-6602-V2 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.
Arrange both the C-5414 Mounting Bracket and the C-0906 Spacer so the smaller screw holes align. Secure both to the C-6602-V2 Vault Bracket so that the C-0906 Spacer is between the machine panel and the C-5414 Mounting Bracket.
Apply the C-5033 Label over the coin drop opening.
I-M0216
Part #: C-6802
Desc 1: FLEX RF Reader Mounting Kit
Desc 2:
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2/F3 Mounting Guide for further instructions.
Instructions do not exist for Kit I-M0241
Connect Power
I-P0007
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the FasCard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
120vac: Connect the blue wire to L1 and the brown wire to N.
240vac: Connect the blue wire to L1 and the brown wire to L2.
Secure the green wire to the ground screw.
Connect the C-5336 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0018
Part #: C-5360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.
Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.
Connect the C-5360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.
I-S0046
Part #: C-6360
Desc 1: Coin Sense Harness
Desc 2: Female taps, Rq. Male
Qty: 1
Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.
Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.
Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.
Connect Machine Interface Harness
I-T0003
Part #: C-5240
Desc 1: Machine Start Harness
Desc 2: Alliance ACA
Qty: 1
Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board.
I-T0086
Part #: C-5265
Desc 1: Machine Start Harness
Desc 2: Alliance MC10 Control
Qty: 1
Part #: C-5266
Desc 1: 6" 18 AWG wire
Desc 2: Jumper for ALS MC10 Control
Qty: 1
Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.
Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.
Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)
Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
Singlevend - Coin Pulse
Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)
Machine Settings
Liquid Soap Supply: Enabled
Payment Settings:
Enable Types: Disable all payment types
Coin Options: Single
Coin 1 Value: Intended Vend Price
Coin 2 Value: Intended Vend Price
Serial Payment System: Disabled
On the FasCard Admin site, create a SingleVend equipment type with the following settings:
Mode: Simple
Pulse Length: 1000
Pulse Interval: 250
Pulse Type: Relay
Sensor Input: Required Off
Show Remaining Time: Disabled
Cycle Time: 600 Seconds
# Pulses: 1
Alliance Touch Controls
Enter the service menu by touch and holding on the top-center of the touch screen for 3 seconds.
Enter password if required.
Configure the machine with the following settings:
Payment Settings:
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
MC10 | SingleVend (Relay) / 1000ms | Alliance Quantum Touch Washer Extractor |