Equipment Serial Integration Support
Overview
CCI supports serial (two-way) communication with many different equipment manufacturer controls. This opens up the following possibilities from the CCI interface (when supported by the control):
Multi-level pricing: Different vend prices for different cycles (i.e. Hot/Warm/Cold) and modifiers (i.e. Extra Rinse/Extra Wash)
Machine Programming: Change machine settings (i.e. cycle times, water levels, temperatures, etc)
If a control is not listed or marked as not supported, it can still be started by the CCI card system using a standard relay pulse.
Alliance (Huebsch, IPSO, Primus, Speed Queen)
Machine Control | Equipment Type | Notes | |
---|---|---|---|
A-Micro | Washer Extractor | Requires special daughter board and micro chip available only from Alliance Laundry Systems. Machine options cannot be configured through CCI interface. | |
B-Micro | - | Control does not support serial interface. | |
Galaxy 200 (Centurion) | - | Control does not support serial interface. | |
Galaxy 400 (Centurion) | - | Control does not support serial interface. | |
Galaxy 600 (Centurion) | Washer Extractor | ||
Galaxy 600 (ACA) | Front-Load Washer | Not supported in LaundryCard v6. | |
Maestro V | Washer Extractor | ||
Micro-Display (MDC) | Front-Load Washer | ||
MDC II (ACA) | Front-Load Washer | Not supported in LaundryCard v6. | |
NetMaster | - | Control does not support serial interface. | |
Quantum Standard (Centurion) | - | Control does not support serial interface. | |
Quantum Silver (Centurion) | Washer Extractor | ||
Quantum Gold (Centurion) | Washer Extractor | ||
Quantum+ (ACA) | Front-Load Washer | Not supported in LaundryCard v6 | |
XControl | - | CCI does not support serial integration. | |
XControl+ | - | CCI does not support serial integration. |
Continental
Machine Control | Equipment Type | Notes | |
---|---|---|---|
Coin Control | Washer Extractor | Requires Continental serial daughterboard. v39/v72 machine firmware recommended. | |
ProfitPlus | Washer Extractor | Requires Continental serial daughterboard. v39/v72 machine firmware recommended. |
Dexter
Machine Control | Equipment Type | Notes | |
---|---|---|---|
A-Series (1.0) | - | Control does not support serial interface. | |
C-Series (1.5) | Washer Extractor | Not supported in LaundryCard v6 Tested against machine firmware level 1.4 |
Laundrylux (Wascomat / Electrolux)
LaundryCard: Re-ordering or adding/disabling cycles is not supported. The default cycles and order must be used.
When connected serially the possibility to make a pause is blocked. Also within the regret time. It is in this case not even possible to activate the pause function by the service program. The configuration setting for pause function (Config 1) will not affect the function of the machine.
Machine Control | Equipment Type | Notes | |
---|---|---|---|
Emerald | Washer | CCI does not support serial interface. | |
Compass (Gen 6) | Washer | 6.50 machine firmware recommended. | |
Compass Pro (Gen 7) | Washer | 8.06 machine firmware recommended. Not supported in LaundryCard v6. | |
Pronto Washer/Dryer | Combo Washer/Dryer | Not supported in LaundryCard v6 | |
CrossOver | Washer | Not supported in LaundryCard v6 |
LG
Machine Control | Equipment Type | Notes | |
---|---|---|---|
Giant-C | Washer | Not supported in LaundryCard v6. | |
Giant-C Plus | Washer | Not supported in LaundryCard v6. | |
Titan | Washer |
| Not supported in LaundryCard v6. |
Maytag / Whirlpool
Machine Control | Equipment Type | Notes | |
---|---|---|---|
Gen 1 | Washer | Super Cycle supported on certain machines. Deluxe Cycle, Ultimate Cycle and Cycle Based Pricing are NOT supported. | |
Gen 2 | - | Not supported by CCI. |
Vending
Machine Control | Equipment Type | Notes | |
---|---|---|---|
MDB Level 1 | ANY | Pricing is set on the vending machine. | |
MDB Level 2 | - | Not supported by CCI. | |
MDB Level 3 | - | Not supported by CCI. |